Agilent 7890 GC with FID & New Headspace Sampler

Includes:

  • Agilent 7890A GC - Refurbished
    • Split/Splitless Inlet
    • Flame Ionization Detector (FID)
  • GC Headspace Sampler (HT2000H) - Brand NEW
    • 42 Position (20ml) headspace vial rack
    • 2.5ml heated headspace syringe
    • Preventative Maintenance Kit - Link
  • G2070 Data system
  • Warranty Coverage

Options:

  • GC Starter Kit
  • Extended PM Kit for Headspace Sampler
  • CFR 21 Part II Compliant Software
  • 1 ml & 5ml Heated Headspace Syringe
  • Liquid, Headspace, or SPME Samplers
  • Workbench - Browse
  • Installation & Familiarization
  • Extended Warranty

More details

Request a Quote

Item#: 11745
Model: 7890
Condition: Refurbished
Manufacturer: Agilent Technologies

Agilent 7890 GC with FID & New Headspace Sampler

The Agilent 7890A Gas Chromatograph offers faster oven cool-down and back flushing allows you to get more done in less time at a lower cost per sample. 5th-generation Electronic Pneumatics Control (EPC) and digital electronics set a new benchmark for pressure set-point and retention time locking precision (0.001 psi) and help make the 7890A one of the most dependable GC ever.

Features:

  • Single Split/Splitless Injector
  • Single Flame Ionization Detector
  • Electronic Pressure Control on detector and injector

NEW GC Headspace Sampler

The high performance, gas-tight heated syringe is a simple and robust system. It eliminates the dead volume and absorption effects, typical of sample loops and transfer lines, which can also impede their detection at very low levels. The syringe only concept allows for sequential injections, even with samples characterized by highly dissimilar features. Even the most chemically active compounds can be analysed, without needing to change any of the sample pathways.

Features:

  • Brand New Condition
  • Compatible with ChemStation
  • Comparable to Agilent & CTC samplers
  • Easy to use
  • Lowest total cost of ownership in the industry
  • GC Mounting Kit & Cables
  • Touch screen
  • Orbital shaking capability
  • LAN and TTL Electrical Control

Specifications:

  • 42 Position
  • Rack for 20ml vials
  • 6 Oven Position
  • Oven Temperature Range: 40-170℃
  • 2.5ml Heated Headspace Syringe
  • HTA Autosampler Manager Software
  • External Pressure Regulator
  • Solvent & Waste vial Kit: Vials, Caps, Septa (1set)
  • Heated Syringe(1pc): 2.5ml plunger & glass barrel

Quote Request for:
Agilent 7890 GC with FID & New Headspace Sampler

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Full Service Reseller

Original Quality at Refurbished Prices! Our refurbished Agilent GC Systems have been expertly restored to meet OEM standards. GenTech Scientific's 60,000 square foot facility stocks an extensive multi-million dollar inventory. We staff knowledgeable sales and service personnel who are committed to help you get the right instrument into your lab. We go beyond the sale with our warranty and continued service options.

We Offer:

  • Warranty Coverage with 48 Hour Response Time
  • Lifetime Phone Support & Remote Troubleshooting
  • Delivery and Installation with Familiarization Training
  • Customized Training to Meet Your Needs
  • Service, Repair, and a Large Inventory of Parts
  • Financing Options: Purchase, Leasing and Rental

How we refurbish used lab instruments

Every refurbished instrument we sell under goes a complete inspection of all electronics and performance review. The instruments undergo in-depth preventative maintenance procedures that include extensive cleaning, detector maintenance, line and pump flushing. Routine maintenance is also addressed and filters, liners, tubing, etc. are all replaced as needed. A full calibration and data verification is performed ensuring our used Agilent GC Systems are returned to excellent working condition.

This pre-owned Agilent 7890 GC with FID & New Headspace Sampler is calibrated to meet OEM standards. Our expert service engineers and chemists can install and custom configure the system to be compliant with the Methods you plan to run.