THC Potency Analyzer 6890 & Headspace

Two Year Warranty Available

Manufacturer: Agilent Technologies

Includes:

  • Agilent 6890 GC - Refurbished
    • Single Split/Splitless Injector
    • Single Flame Ionization Detector
    • Electronic Pressure Control on detector and injector
    • HPIB Communications installed on GC
    • Analytical column for determination of Cannabinol
    • G2070 Data System
  • GC Headspace Sampler - Brand NEW
    • 42 Positions
    • Rack for 20ml vials
    • 6 Oven Position
    • Oven Temperature Range: 40-170℃
    • Starter Kit: 20ml vials, caps, septa (10pcs)
    • LAN and TTL Electrical Control
    • Preventative Maintenance Kit - Link
  • Manuals
  • One (1) Year Warranty

Options:

  • Two (2) Year Warranty Available
  • Installation & Familiarization
  • Extended PM Kit for Headspace Sampler
  • GC Starter Kit
  • GC Chemstation Driver (Rev.B)
  • MSD Chemstation Driver (Rev.E)
  • CFR 21 Part II Compliant Software
  • 1 ml & 5ml Heated Headspace Syringe

More details

Request a Quote

Item#: 11411
Condition: Refurbished

Quote Request for:
THC Potency Analyzer 6890 & Headspace

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

THC Potency Analyzer 6890 & Headspace

Determination of Cannabinol - Pharmacologically, the principal psychoactive constituent of cannabis is tetrahydrocannabinol (THC), which is the most widely used illegal psychoactive drug in the United States. THC is only one of 400 compounds in the plant, including other cannabinoids, such as cannabidiol (CBD) and cannabinol (CBN). Consumption of cannabis has both psychoactive and physiological effects. The minimum amount of THC required to have a perceptible psychoactive effect is about 10 micrograms per kilogram of body weight. Although THC is typically considered the primary active component of the cannabis plant, various scientific studies suggest that certain other cannabinoids, like CBD, may also play a significant role in its psychoactive effects. For this reason, its precise recognition and quantification is fundamental.

The Agilent/HP 6890 series GC features electronic pneumatic control of all gas pressures and flows. On board sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results. By providing stable results, EPC reduces re-calibration frequency and improves laboratory productivity.

6890 GC Features:

  • Single Split/Splitless Injector
  • Single Flame Ionization Detector
  • Electronic Pressure Control on detector and injector
  • HPIB Communications

NEW GC Headspace Sampler

The high performance, gas-tight heated syringe is a simple and robust system. It eliminates the dead volume and absorption effects, typical of sample loops and transfer lines, which can also impede their detection at very low levels. The syringe only concept allows for sequential injections, even with samples characterized by highly dissimilar features. Even the most chemically active compounds can be analysed, without needing to change any of the sample pathways.

Features:

  • Brand New Condition
  • Compatible with ChemStation
  • Comparable to Agilent & CTC samplers
  • Easy to use
  • Lowest total cost of ownership in the industry
  • GC Mounting Kit & Cables
  • Touch screen
  • Orbital shaking capability
  • LAN and TTL Electrical Control

Specifications:

  • 42 Position
  • Rack for 20ml vials
  • 6 Oven Position
  • Oven Temperature Range: 40-170℃
  • 2.5ml Heated Headspace Syringe
  • HTA Autosampler Manager Software
  • External Pressure Regulator
  • Solvent & Waste vial Kit: Vials, Caps, Septa (1set)
  • Heated Syringe(1pc): 2.5ml plunger & glass barrel