Agilent 1100 Capillary Pump (G1376A)
Includes:
- Agilent 1100 Capillary Pump (G1376A)
- CAN Cable
- *Cover NOT Included
- In-House Warranty Coverage
Options:
- Installation & Familiarization
- Extended Warranty
MENU
This system, based on the reliable Agilent 1100 Series HPLC system, uses a unique pump technology that optimizes the system for capillary LC, offering a high level of sensitivity and reproducibility. The Agilent 1100 Series capillary pump incorporates an electronic flow control (EFC) that measures and controls the actual flow rate, rather than depending on calculations. This assures flow rate stability throughout the analysis. The pump provides flow rates from 1µl/min up to 100µl/min, with full gradient capability for capillary LC and 2.5ml/min in normal mode for a wide range of flexibility.
Hydraulic system | Two dual pistons in series, with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve, solvent selection valve and electronic flow control (EFC) for flow rates up to 100 µl/min |
Settable column flow range | 0.01 – 20 µl/min, 0.01 – 100 µl/min (with extended flow range kit), 0.001 – 2.5 ml/min (electronic flow control bypassed) |
Recommended column flow range | 1–20 µl/min, 10–100 µl/min (with extended flow range kit) |
Column flow precision | < 0.7 % RSD or 0.03 SD, whatever is greater (typically < 0.4 % RSD or 0.02 SD), at 10 µl/min and 50 µl/min column flow (based on RT, default settings) |
Composition precision | < 0.2 % SD at 10 µl/min, 50 µl/min (with extended flow range kit) and 1 ml/min (default settings) |
Pressure range | up to 400 bar system pressure |
Delay volume | Typically 3 µl from EFC to pump outlet for flow rates up to 20 µl/min; 12 µl from EFC to pump outlet for flow rates up to 100 µl/min; 180–480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min; mixer delay volume 420 µl |
pH range | 1.0 to 8.5 recommended |
The Agilent 1100 Capillary Pump ( Cap Pump) is in excellent condition. A unique pump design offers better control and flexibility of low flow rates. This pump is ideally suited for capillary LC and LC/MS applications, like bio-pharmaceutical research, where sample volumes are limited and higher sensitivity is essential.
Original Quality at Refurbished Prices! Our refurbished Agilent HPLC Modules have been expertly restored to meet OEM standards. GenTech Scientific's 60,000 square foot facility stocks an extensive multi-million dollar inventory. We staff knowledgeable sales and service personnel who are committed to help you get the right instrument into your lab. We go beyond the sale with our warranty and continued service options.
Every refurbished instrument we sell under goes a complete inspection of all electronics and performance review. The instruments undergo in-depth preventative maintenance procedures that include extensive cleaning, detector maintenance, line and pump flushing. Routine maintenance is also addressed and filters, liners, tubing, etc. are all replaced as needed. A full calibration and data verification is performed ensuring our used Agilent HPLC Modules are returned to excellent working condition.
This pre-owned Agilent 1100 Capillary Pump (G1376A) is calibrated to meet OEM standards. Our expert service engineers and chemists can install and custom configure the system to be compliant with the Methods you plan to run.