Agilent 1100 LC System with Binary Pump & VWD

Two Year Warranty Available

Manufacturer: Agilent Technologies

Includes:

  • Agilent 1100 LC System 
    • 1100 Solvent Tray
    • 1100 Binary Pump
    • 1100 Vacuum Degasser
    • 1100 Autosampler
    • 1100 Variable Wavelength Detector (VWD)
  • G2170 Data System
  • Manuals
  • One (1) Year In-House Warranty

Options:

  • 1100 Series Column Compartment
  • Two (2) Year In-House Warranty Available
  • Installation & Familiarization

More details

Request a Quote

Item#: 10108
Condition: Refurbished

Quote Request for:
Agilent 1100 LC System with Binary Pump & VWD

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Agilent 1100 LC System with Binary Pump & VWD

The Agilent 1100 (HP 1100) is an innovative series of stackable HPLC components designed to be controlled  via handheld controller  or computer running ChemStation.  System can be used as a stand-alone, or with computer and ChemStation.  Single components are also available.

The variable wavelength detector (VWD) lowers detection limits with simplified optics for high sensitivity, low baseline drift and wide linear range. Lower your cost of ownership with easy front access to lamp and flow cell for fast replacement. Helps to comply to GLP with built-in holmium oxide filter for automatic wavelength verification.

Our Agilent/HP HPLC Systems are in excellent condition and come fully tested and refurbished at GenTech Scientific. 

VWD Features:

Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and
task-oriented information.

Robust materials withstand most demanding applications - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime.Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.

Wide flow range - up to 10 ml/min for broad HPLC work, including semipreparative separations.

More help for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.

VWD Specifications:

Detector type:Double beam
Light source:Deuterium lamp
Short-term noise:± 0.75 x 10-5AU at 254 nm
Drift:3 x 10-4 AU/h at 254 nm
Linearity:> 2 AU upper limit
Wavelength range:190 – 600 nm
Wavelength accuracy:±1 nm, self-calibration with deuterium, lines, verification with Holmium oxide filter
Slit width:6.5 nm typical
Flow cells:Standard: 14 μl, volume, 10 mm cell path length, 40 bar (588 psi) pressure maximum
Semi-micro: 5 μl, volume, 6 mm cell path length, 40 bar (588 psi) pressure maximum
Micro: 1 μl, volume, 5 mm cell path length, 40 bar (588 psi) pressure maximum
High pressure: 14 μl, volume, 10 mm cell path length, 400 bar (5880 psi) pressure maximum
Time programmable:Wavelength, polarity, peak width, lamp on/off
Spectral tools:Stop-flow wavelength scan
Analog output:Recorder/Integrator 100 mV or 1 V, 1 output
Specials:Optional cuvette holder