GC/MS for Semivolatile Organic Compounds Environmental Testing

Two Year Warranty Available

Manufacturer: Agilent Technologies

Includes:

  • Agilent 5973 MSD
    • EI Source
    • Diffusion Pump
    • Heated transfer line
  • Agilent 6890 GC
    • Split/Splitless Injector w/EPC
    • G1701 Data System
  • HPIB/LAN Communication
  • Mechanical Pump
  • Ninety (90) Day Warranty

Options:

  • Two (2) Year Warranty Available
  • Installation & Familiarization
  • High Performance Turbo Pump
  • Autosampler (AS)
  • Mass Spec Workbench with Vacuum Pump Noise Enclosure

More details

Request a Quote

Item#: 11223a
Condition: Refurbished

Quote Request for:
GC/MS for Semivolatile Organic Compounds Environmental Testing

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

GC/MS for Semivolatile Organic Compounds Environmental Testing

For environmental labs looking for an all-in-one GC/MS package to handle their SVOCs testing needs, the Agilent 5973N benchtop mass spectrometer with 6890 gas chromatograph is the perfect fit. This system is the workhorse of the mass spec, easily handling EPA Method 8270 apparatus requirements. 

Accurate, reproducible quantitation. Fast scan speed and a response that is linear over 4 orders of magnitude assure accurate, reproducible quantitation, even in complex sample matrices such as wastewater, food, and physiological fluids. The programmable temperature vaporization (PTV) inlet offered with the HP 6890 Series GC expands the limits of GC/MS detection by allowing large-volume injections, up to 1 mL.

Productive, time-saving tools. The HP MSD Productivity ChemStation software automates routine instrument control and data interpretation tasks for high productivity. Moreover, the system can be completely automated, from injection through final report, for unattended operation, 24 hours a day.

Specifications:

Mass range: Scans any mass range between 1.6 - 800 amu in 0.1-amu steps.

Dynamic range: Linear Dynamic Range: Calibration curves are linear over 4 orders of magnitude. Total ADC dynamic range is 6 orders of magnitude.

Full scan sensitivity - electron impact ionization: 1 pg of octafluoronaphthalene shall yield a signal-to-noise ratio of at least 10:1 RMS.

Selected ion monitoring (SIM) sensitivity - electron impact ionization: 20 fg of octafluoronaphthalene shall yield a signal-to-noise ratio of at least 10:1 RMS when 272 m/z is monitored.

Features:

  • EI Source
  • MS features a mass range of 10-800 amu
  • Heated Source and Transferline
  • Heated Hyperbolic Quadrupole Mass Filter
  • High-Energy Dynode (HED) Electron Multiplier Detector

This Agilent 5973 MSD 6890 GC comes fully refurbished and tested at GenTech Scientific.