Proteomics Mass Spectrometer

Two Year Warranty Available

Manufacturer: Thermo Scientific

Includes:

  • Thermo LTQ Orbitrap XL with ETD &  XL Mass Spec
    • Max Resolution > 100,000
    • ETD Module
    • IonMax ESI Source
    • Two (2) Mechanical Pumps
    • Chiller
    • Powervar 2000 GPI
  • Xcalibur Data System
  • Cables & Manuals
  • Ninety (90) Day Warranty

Options:

  • Two (2) Year Warranty Available
  • Nitrogen Generator
  • POWERVAR Series UPS
  • Source Options:
    • Nano or APCI Source
  • Installation & Familiarization
  • Extended Warranty

More details

Request a Quote

Item#: 10944a
Model: LTQ Orbitrap
Condition: Refurbished

Rental Option

Short and Long term options available.
Request a quote today - Click Here

Quote Request for:
Proteomics Mass Spectrometer

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Proteomics Mass Spectrometer

Thermo Scientific's LTQ Orbitrap XL ETD is the most powerful instrument for proteomics analyses: It combines three different and complementary fragmentation techniques CID, HCD, and ETD with the proven benefits of Orbitrap technology. 

Combining fast, sensitive linear ion trap MSn with high-resolution, accurate-mass (HR/AM) Orbitrap technology, the research-proven Thermo Scientific LTQ Orbitrap XL system provides economical access to the power of hybrid ion trap-Orbitrap analysis. With outstanding mass accuracy, resolving power, high sensitivity and MSn capability, the LTQ Orbitrap XL instrument is the instrument of choice for confident, reliable detection, identification, and characterization. The standard higher-energy collisional dissociation (HCD) collision cell provides exceptional flexibility in fragmentation for advanced proteomics and small-molecule research. The electron transfer dissociation (ETD) generates complementary information for highly sensitive PTM analyses and de novo sequencing.

Specifications:

  • Resolution (apodized)
    • 60000 (FWHM) @ m/z 400 with a scan repetition rate of 1 second
    • Minimum resolution 7500@ m/z 400
    • Maximum resolution 100000 @ m/z 400
  • Cycle Time 
    • 1 scan at 60000 resolution @ m/z 400 per second
  • Mass Range 
    • m/z 50–2000
    • m/z 200–4000
  • Mass Accuracy 
    • <3 ppm RMS for 2 h period with external calibration using defined conditions
    • <2 ppm RMS with internal calibration
  • Dynamic Range 
    • >10000 between mass spectra,
    • >4000 between highest and lowest detectable mass in one spectrum
  • MS/MS 
    • MS/MS and MSn scan functions