Agilent 6890/5975 GC/MS with Tekmar Atomx Purge & Trap

Two Year Warranty Available

Manufacturer: Agilent Technologies

Includes:

  • Agilent 5975 Inert MSD
    • Heated Transfer Line
    • Mass range 10-650 amu
    • High Performance Turbo Pump
    • LAN Communication
    • EI Source
  • Agilent 6890 Plus GC
    • S/S Inlet with EPC
    • LAN Communication
  • Tekmar Atomx Purge & Trap 
    • 80 position sampler
    • NEW in the box, never used
  • G1701 Data System
  • Mechanical pump
  • Cables & Manuals
  • Ninety (90) Day Warranty

Options:

  • Two (2) Year Warranty Available
  • Installation & Familiarization

More details

Request a Quote

Item#: 11700
Model: 6890, 5975
Condition: Refurbished

Quote Request for:
Agilent 6890/5975 GC/MS with Tekmar Atomx Purge & Trap

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Agilent 6890/5975 GC/MS with Tekmar Atomx Purge & Trap

The Agilent/HP 6890 GC features electronic pneumatic control of all gas pressures and flows. On-board sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results.

  • Mass range 10-650 amu
  • Ambient temperature +4 ℃ to 450 
  • Temperature set point resolution: 1 

The Agilent 5975 MSD with the 6890 GC is a high performance, full-featured system optimized for complex EI analyses. This systems come fully refurbished and tested at GenTech Scientific.

Tekmar Atomx Purge & Trap

The Atomx Automated VOC Sample Preparation system combines an Autosampler and Purge and Trap into a single instrument for the analysis of VOCs in soils and waters. This is the first of its kind and only system that employs a unique methanol extraction automation feature for high level soils in accordance with USEPA Method 5035.  

Features

  • Capable of sampling low level and high level soil samples
  • Only system to automate labor intensive Methanol Extractions
  • Utilizes proven 80-position carousel design for optimal throughput
  • Utilizes a digital Mass Flow Controller (MFC) for independent mode flow control
  • Chiller options available for EPA requirements
  • Ability to vary sample volume in 1mL aliquots from 1-25mL
  • Reduce carryover with Extractasol - dedicated methanol port for rinsing needle, sample lines, and glassware
  • Water reservoir included with standard instrument package
  • Three - 15mL UV-protected standard spiking vessels prevent possible compound break-down. Capable of varying volume delivery in 1, 2, 5, 10, and 20µL aliquots with zero waste
  • Shortest soil pathway on the market
  • Automated system leak check diagnostics
  • CFR compliance tools available
  • Small footprint saves bench space