Agilent 5973N MSD 6890 GC

Two Year Warranty Available

Manufacturer: Agilent Technologies

Includes:

  • Agilent 5973N MSD
    • EI Source
    • LAN Communications
    • MS features a mass range of 10-800 amu
    • Heated Source and Transferline
    • Heated Hyperbolic Quadrupole Mass Filter
    • High-Energy Dynode (HED) Electron Multiplier Detector
    • High Performance Turbo Pump
  • Agilent 6890 GC with Split/Splitless Injector and Electronic Pressure Control
  • G1701 Data System
  • NEW Roughing Pump
  • Ninety (90) Day Warranty

Options:

  • Two (2) Year Warranty Available
  • Agilent 7683 Autosampler (AS)
  • Security Plus Series UPS 5200W-Battery Back-up Power Supply
  • Quiet Mass Spec Workbench with Noise Enclosure

More details

Request a Quote

Item#: 10715
Condition: Refurbished

Quote Request for:
Agilent 5973N MSD 6890 GC

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Agilent 5973N MSD 6890 GC

For analysts looking for an all-in-one GC/MS package, the Agilent 5973N benchtop mass spectrometer is the perfect fit. The 5973 is the workhorse of the mass spec world with unmatched reliability and service support.

Accurate, reproducible quantitation. Fast scan speed and a response that is linear over 4 orders of magnitude assure accurate, reproducible quantitation, even in complex sample matrices such as wastewater, food, and physiological fluids. The programmable temperature vaporization (PTV) inlet offered with the HP 6890 Series GC expands the limits of GC/MS detection by allowing large-volume injections, up to 1 mL.

Productive, time-saving tools. The HP MSD Productivity ChemStation software automates routine instrument control and data interpretation tasks for high productivity. Moreover, the system can be completely automated, from injection through final report, for unattended operation, 24 hours a day.

Specifications:

Mass range: Scans any mass range between 1.6 - 800 amu in 0.1-amu steps.

Dynamic range: Linear Dynamic Range: Calibration curves are linear over 4 orders of magnitude. Total ADC dynamic range is 6 orders of magnitude.

Full scan sensitivity - electron impact ionization: 1 pg of octafluoronaphthalene shall yield a signal-to-noise ratio of at least 10:1 RMS.

Selected ion monitoring (SIM) sensitivity - electron impact ionization: 20 fg of octafluoronaphthalene shall yield a signal-to-noise ratio of at least 10:1 RMS when 272 m/z is monitored.

Features:

  • EI Source
  • LAN Communications
  • MS features a mass range of 10-800 amu
  • Heated Source and Transferline
  • Heated Hyperbolic Quadrupole Mass Filter
  • High-Energy Dynode (HED) Electron Multiplier Detector

This Agilent 5973N MSD 6890 GC with Standard Turbo Pump comes fully refurbished and tested at GenTech Scientific.