Agilent 5975C with 6890 GC & G1888A Headspace

Includes:

  • Agilent 5975C MSD 
    • Diffusion Pump
  • Agilent 6890
    • S/S inlet with EPC
  • Agilent G1888A Autosampler
    • 70 Position Autosampler
  • Data System
  • Warranty Coverage

Options:

  • GC Starter Kit
  • Liquid, Headspace, or SPME Samplers
  • Workbench - Browse
  • Installation & Familiarization
  • Extended Warranty

More details

Request a Quote

Item#: 11479
Condition: Refurbished
Manufacturer: Agilent Technologies

Finance Badge

Agilent 5975C with 6890 GC & G1888A Headspace

The 5975 MSD not only scans up to 1050µ but it does so with accuracy and precision. The proprietary hyperbolic quadrupole design ensures the necessary resolution to produce classical isotope ratios and accurate mass assignment across the entire mass range; the high mass test kit provides assurance of correct mass assignments. The sensitivity and ruggedness of the 5975 MSD make it especially ideal for analyzing active compounds such as pesticides and drugs in complex matrices.  The system includes the Agilent 6890N GC.

5975C Features:

  • True hyperbolic quadrupole maximum transmission and resolution
  • Thermally stable quartz quadrupole the proprietary quadrupole can be heated up to 200℃ for long-term mass axis stability
  • Fast scanning capability scan rates up to 10,000 µ/sec
  • Electron impact (EI) ionization source
  • 1050µ mass range extends application space for high mass compounds

6890 Features:

  • Operating Temperature: Ambient +4℃ to 450℃. (Maximum for S/S Inlet : 400℃)
  • Dual channel design supports two inlets and two detectors.
  • Full range digital data output enables the smallest and largest peaks to be quantitated in a single run.
  • A run time deviation log is created for each analysis to ensure that all method parameters were achieved and maintained.

Temperature control of the 6890N oven allows for fast and precise temperature ramping. Overall thermal performance provides optimal chromatography including peak symmetry, retention time repeatability, and retention index accuracy. The combination of precise pneumatic control and accurate temperature control leads to outstanding retention time repeatability, the basis for all chromatographic measurement

G1888 Features:

  • 70 sample tray
  • 12 sample positions in heating oven
  • Automated constant heating
  • Maximum sample throughput in the minimum amount of time
  • Temperature range from 40℃ to 230℃
  • Multi-puncture extraction

The Agilent G1888 Network Headspace Sampler features an inert sample pathway for superior chemical performance without analyte degradation or loss. Its high sample capacity and increased sensitivity provide excellent performance over a wide range of analyses. The total solution-from sampling to data analysis to reporting-gives you the highest confidence in your results.

Quote Request for:
Agilent 5975C with 6890 GC & G1888A Headspace

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Full Service Reseller

Original Quality at Refurbished Prices! Our refurbished GC/MS Systems have been expertly restored to meet OEM standards. GenTech Scientific's 60,000 square foot facility stocks an extensive multi-million dollar inventory. We staff knowledgeable sales and service personnel who are committed to help you get the right instrument into your lab. We go beyond the sale with our warranty and continued service options.

We Offer:

  • Warranty Coverage with 48 Hour Response Time
  • Lifetime Phone Support & Remote Troubleshooting
  • Delivery and Installation with Familiarization Training
  • Customized Training to Meet Your Needs
  • Service, Repair, and a Large Inventory of Parts
  • Financing Options: Purchase, Leasing and Rental

How we refurbish used lab instruments

Every refurbished instrument we sell under goes a complete inspection of all electronics and performance review. The instruments undergo in-depth preventative maintenance procedures that include extensive cleaning, detector maintenance, line and pump flushing. Routine maintenance is also addressed and filters, liners, tubing, etc. are all replaced as needed. A full calibration and data verification is performed ensuring our used GC/MS Systems are returned to excellent working condition.

This pre-owned Agilent 5975C with 6890 GC & G1888A Headspace is calibrated to meet OEM standards. Our expert service engineers and chemists can install and custom configure the system to be compliant with the Methods you plan to run.