Dionex Ion Chromatography System for UV & Conductivity

Manufacturer: Dionex

Includes:

  • Dionex AS50 Autosampler
    • 100 position sample tray
  • Dionex AS50 Thermal Compartment
  • Dionex EG40 Eluent Generator
  • Dionex ED50 Electrochemical Detector
  • AD25 Absorbance Detector
  • Dionex GP50 Gradient Pump
  • AC2 Power Control Accessory
  • Chromeleon Data System
  • One (1) Year In-House Repair Warranty

Options: 

  • PC Pneumatic Controller
  • Installation & Familiarization
  • Extended Warranty

More details

Request a Quote

Item#: 11488
Condition: Refurbished

Quote Request for:
Dionex Ion Chromatography System for UV & Conductivity

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Dionex Ion Chromatography System for UV & Conductivity

Dionex AS50 Autosampler

The Dionex Autoselect AS50 Autosampler precisely delivers from 1.0 to 99.9 µL (in 0.1 µL increments) or 100 to 1000 µL (in 1 µL increments) of sample to an injection valve. During sampling, the tray remains stationary and a sampling needle arm moves from vial to vial. Up to 99 injections can be taken from each vial. The AS50 can be controlled locally, from the front panel keypad and display, or remotely, with a personal computer running Chromeleon software. The AS50 can be configured with PEEK flow paths and components for ion chromatography (IC) applications, or with stainless steel flow paths and components for high-performance liquid chromatography applications (HPLC).

  • Delivers 1.0-99.9 µL (in 0.1 µL increments) or 100-1000 µL (in 1 µL increments) of sample to an injection valve100 position sample tray

AS50 Thermal Compartment

A Peltier device controls the compartment temperature to between 10 °C and 40 °C (PEEK systems) or 10 °C and 80 °C (stainless steel systems). The device can cool the compartment to a minimum of 10 °C below ambient and heat it to a maximum of 60 °C above ambient. A heat exchanger equilibrates the sample temperature before it enters the column.

Dionex EG40 Eluent Generator

The use of eluent generators in IC has several significant advantages. Separations can be performed using only deionized water as the carrier. Eluent generators produce high purity, containment free acid and base eluents on-line. The use of these high purity eluents can significantly improve the performance of ion chromatography methods.

  • Operating pressure: 2000 psi(14MPa) - 3000 psi (21MPa)

Dionex ED50 Electrochemical Detector

The ED50 Electrochemical Detector measures current resulting from the application of potential (voltage) across electrodes in flow-through cells. Depending on the method by which the potential is applied and the current measured, several different properties of the flowing solution can be determined.

The ED50 provides the three major forms of electrochemical detection: conductivity, DC amperometry, and integrated amperometry. Pulsed amperometry is a form of integrated amperometry.

  • Conductivity detection is based on the measurement of the magnitude of electrical current carried by dissolved ions in an electric field.
  • DC Amperometric detection is based on the measurement of current resulting from oxidation or reduction (electrolysis) of analyte molecules at the surface of an electrode.
  • Integrated and pulsed amperometric detection are similar to DC Amperometry in that molecules are oxidized or reduced at the surface of an electrode. However, current is measured by integration during a portion of a repeating potential vs. time waveform.

Dionex GP50 Gradient Pump

The GP50 Gradient Pump is an integral part of a Dionex chromatography system. It is a microprocessor-based, dual-piston, variable-speed, gradient delivery system designed to blend and pump mixtures of up to four different eluents at precisely controlled flow rates. The pump can deliver the selected eluent composition isocratically, or as a multistep linear or curved gradient. A Digital Signal Processor (DSP) provides high speed control of pump flow and pressure.

  • Designed to blend and pump mixtures of up to four different eluents at precisely controlled flow rates