Waters Xevo G2-S Q-ToF MS with Maximize

Waters Xevo G2-S Q-ToF MS with Acquity UPLC

Includes:

  • Waters Xevo G2-S QTof MS
    • ESI Probe
    • Mass Range: m/z 20 to 100,000
  • Waters Acquity UPLC H-Class
    • Quaternary Solvent Manager
    • Column Manager
    • Column Heater
  • MassLynx Data System
  • N2 Generator
  • Warranty Coverage

Options:

  • Mass Spec Workbench - Browse
  • Installation & Familiarization
  • Extended Warranty

More details

Request a Quote

Item#: 11820
Model: Xevo G2-S
Condition: Refurbished
Manufacturer: Waters

Waters Xevo G2-S Q-ToF MS with Acquity UPLC

Xevo G2-S QTof incorporates StepWave ion optics for unsurpassed levels of durable sensitivity and proven quantitative time-of-flight (QuanTof) technology to deliver superior UPLC-compatible mass resolution, matrix-tolerant dynamic range, quantitative performance, mass accuracy, and speed of analysis – simultaneously.

Xevo G2-S QTof delivers not only conventional MS and MS/MS methods of data acquisition, but it also has the ability to perform UPLC/MSE to collect the maximum amount of data from a single analysis. UPLC/MSE datasets provide a comprehensive digital record of your sample. The system incorporates IntelliStart Technology, for automated system optimization and status monitoring, ensuring that the highest quality data is routinely available to all levels of operators.

The instrument is equipped with a high resolution, high stability quadrupole analyzer (MS1), plus pre-filters to maximize resolution and transmission while preventing contamination. The instrument is also equipped with a high-performance oaTof mass analyzer (MS2) with a mass range up to m/z 100,000 and resolving power of >32,500 FWHM.

Specifications:
Acquisition ModesMS scanning
MS/MS product ion scanning
UPLC/FastDDA (rapid, automated MS to MS/MS scan function switching): UPLC/MS
Ionization mode switching (ESCi)
External contact start/stop/events
Analog channel acquisition via an e-SAT/IN module
Mass RangeThe TOF mass range is m/z 20 to 100,000
The quadrupole mass range is m/z 20 to 16,000 in non-resolving mode and m/z 20 to 4,000 in resolving mode.
A high mass quadrupole option is available with a mass range up to m/z 100,000 in non-resolving mode and m/z 32,000 in resolving mode
Mass Measurement AccuracyThe mass measurement accuracy of the instrument, in resolution mode, will be better than 1 ppm RMS, based on 10 consecutive repeat measurements of the [M + Na]+ ion of raffinose (m/z 527.1588), using a suitable choice of lock mass.
Dynamic RangeThe dynamic range, defined as the range of peak intensities that will give better than 3 ppm RMS for 10 sec of data, is at least four orders of magnitude when measured on the m/z 556.2771 peak from leucine enkephalin. This can be increased with use of programmable dynamic range >enhancement (pDRE) technology.
Mass ResolutionResolution Mode: >32,500 FWHM measured on the (M + 6H)6+ isotope cluster from bovine insulin (m/z 956) at a data acquisition rate of 30 spectra per second.
Sensitivity Mode: >22,500 FWHM measured on the (M + 6H)6+ isotope cluster from bovine insulin (m/z 956) at a data acquisition rate of 30 spectra per second.
MS Sensitivity (ESI+)The peak at m/z 556 from a solution of 50 pg/μL leucine enkephalin in 50/50 acetonitrile/water + 0.1% formic acid, will have an intensity of greater than 6,400 counts per sec. The instrument will be tuned to >32,500 FWHM resolution (as demonstrated on bovine insulin) and the mass range
will be set to m/z 1200.

The peak at m/z 556 from a solution of 50 pg/μL leucine enkephalin in 50/50 acetonitrile/water + 0.1% formic acid, will have an intensity of greater than 32,000 counts per sec. The instrument will be tuned to >22,500 FWHM resolution (as demonstrated on bovine insulin) and the mass range will be set to m/z 1200.
MS Sensitivity (ESI-)The peak at m/z 503 from a solution of 500 pg/μL raffinose in 70/30 acetonitrile/water (no additives), will have an intensity of greater than 7,200 counts per second. The instrument will be tuned to >32,500 FWHM resolution (as demonstrated on bovine insulin), and the mass range will be set to m/z 1200.

The peak at m/z 503 from a solution of 500 pg/μL raffinose in 70/30 acetonitrile/water (no additives), will have an intensity of greater than 36,000 counts per second. The instrument will be tuned to >22,500 FWHM resolution (as demonstrated on bovine insulin), and the mass range will be set to m/z 1200.
MS/MS SensitivityUsing a [Glu1] -Fibrinopeptide B solution of 100 fmol/μL with the instrument tuned for 32,500 resolution (as demonstrated on bovine insulin), the intensity of the most intense y” sequence ion from the MS/MS spectrum of the doubly charged precursor ion (785.8 Da) will be greater than 500 counts per second.

Quote Request for:
Waters Xevo G2-S Q-ToF MS with Acquity UPLC

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?

Full Service Reseller

Original Quality at Refurbished Prices! Our refurbished LC/MS Systems have been expertly restored to meet OEM standards. GenTech Scientific's 60,000 square foot facility stocks an extensive multi-million dollar inventory. We staff knowledgeable sales and service personnel who are committed to help you get the right instrument into your lab. We go beyond the sale with our warranty and continued service options.

We Offer:

  • Warranty Coverage with 48 Hour Response Time
  • Lifetime Phone Support & Remote Troubleshooting
  • Delivery and Installation with Familiarization Training
  • Customized Training to Meet Your Needs
  • Service, Repair, and a Large Inventory of Parts
  • Financing Options: Purchase, Leasing and Rental

How we refurbish used lab instruments

Every refurbished instrument we sell under goes a complete inspection of all electronics and performance review. The instruments undergo in-depth preventative maintenance procedures that include extensive cleaning, detector maintenance, line and pump flushing. Routine maintenance is also addressed and filters, liners, tubing, etc. are all replaced as needed. A full calibration and data verification is performed ensuring our used LC/MS Systems are returned to excellent working condition.

This pre-owned Waters Xevo G2-S Q-ToF MS with Acquity UPLC is calibrated to meet OEM standards. Our expert service engineers and chemists can install and custom configure the system to be compliant with the Methods you plan to run.