Agilent 1290 Infinity Binary Pump with Thermostat and TCC

Includes:

  • Agilent 1290 Infinity LC Front End
    • 1290 Solvent Tray
    • 1290 Binary Pump with built in degasser (G4220A)
    • 1290 Autosampler (G4226A)
    • 1290 Autosampler Thermostat (G1330B)
    • 1290 Thermostatted Column Compartment (G1316C)
  • Cables & Manuals
  • One (1) Year In-House Warranty

Options:

  • 1290 Column Compartment
  • Mass Spec Workbench
  • Generator
  • Installation & Familiarization
  • Extended Warranty

More details

Request a Quote

Item#: 11791
Model: 1290
Condition: Refurbished
Manufacturer: Agilent Technologies

Agilent 1290 Infinity Binary Pump with Thermostat and TCC

The Agilent 1290 Infinity Binary Pump comprises two identical pumps integrated into one housing. Binary gradients are created by high- pressure mixing. A degassing unit is included for applications that require best flow stability, especially at low flow rates, for maximum detector sensitivity. The flow path of the pump has been optimized for minimal delay of gradients. Typical applications are high throughput methods with fast gradients on high resolution 2.1 mm columns. A solvent selection valve allows forming binary mixtures (isocratic or gradient) from one of two solvents per channel.

  • Pressure operating range: 1200 bar
  • Setable flow range:  Set points 0.001 – 5 mL/min
  • Flow range 0.05 – 5.0 mL/min
  • Flow accuracy ± 1 % or 10 µL/min

The Agilent 1290 Infinity Thermostat is designed for use with other modules of the Agilent 1200 Infinity Series or with other LC systems. The specially- designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials.

  • Temperature range: Settable from 4 °C to 40 °C in 1 ° increments 
  • Temperature accuracy at ambient temperatures < 25 °C and humidity < 50 %: 3 °C to 8 °C at a setpoint of 4 °C* 
  • Temperature accuracy at ambient temperatures < 30 °C and humidity < 60 %: 3 °C to 9 °C at a setpoint of 4 °C*

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC.

  • Temperature range: 10 degrees below ambient to 100 °C
  • Temperature stability ± 0.05 °C
  • Temperature accuracy ± 0.8 °C or ± 0.5 °C with calibration
  • Column capacity: Three 30 cm

Quote Request for:
Agilent 1290 Infinity Binary Pump with Thermostat and TCC

Please complete the form below to request more information and pricing.


Do you have an instrument to Trade-In?