Agilent 1290 tcc right angle
Agilent 1290 tcc cover off
Certified Refurbished · Liquid Chromatography · HPLC Modules

Agilent 1290 Thermostatted Column Compartment (TCC) G1316C

$3,495.00




The Agilent 1290 Infinity Thermostatted Column Compartment (TCC), G1316C, is an ultra-high-pressure liquid chromatography column oven engineered to deliver ultra-precise, high-speed temperature control for demanding UHPLC applications.

Includes:

  • Agilent 1290 Thermostatted Column Compartment (TCC) G1316C
    • CAN Cable
  • In-House Warranty Coverage
Verified against OEM and published benchmarks
1-year warranty available
Installation and familiarization available
Financing available

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 1290 Infinity G1316C Thermostatted Column Compartment (TCC). Comes with CAN cable and warranty coverage. This module holds the column at a set temperature up to 100°C, with hardware tuned to reduce dispersion at low flow rates.

Every unit we sell moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent engineered the 1290 Infinity Thermostatted Column Compartment to meet the rigorous thermal demands of high-throughput, high-pressure separations where structural column stability is paramount. Agilent highlights this module for its advanced Peltier cooling and heating architecture, which allows for rapid temperature transitions and excellent spatial uniformity across a broad temperature range. Incorporating ultra-low volume, high-pressure pre-heating capillaries, the G1316C eliminates the thermal mismatch between the mobile phase and the column packing that typically causes peak distortion at high linear velocities. It stands as an elite thermal management module featuring built-in leak protection, valve automation capabilities, and full compatibility with 1200-bar UHPLC workflows.

What this module does

Rather than a standard heated enclosure, the Agilent G1316C functions as a highly precise environmental and fluidic stabilization module within a Ultra-High-Performance Liquid Chromatography (UHPLC) stack. Positioned directly between the high-pressure autosampler and the detector, its primary job is to actively regulate column temperatures and pre-condition incoming solvents under extreme hydraulic pressures. This process executes several critical system-wide functions:

  • Eliminates Thermal Gradients: It utilizes powerful dual Peltier elements and convective air circulation to maintain a completely uniform column environment, preventing peak broadening across long multi-vial runs.
  • Minimizes Extra-Column Volume: It employs optimized 1.6 µL high-pressure pre-heating capillaries that match solvent temperature to the column setpoint, maintaining excellent peak capacity without adding system dispersion.
  • Automates Method Development: It can accommodate internal high-pressure switching valves (up to 1200 bar), allowing operators to automatically toggle between up to eight columns for rapid method scouting.
  • Protects Column Integrity: It features a smart electronic column tag reader that automatically records injection counts, max pressures, and operational history to prevent catastrophic column failure and simplify GLP auditing.
In this listing
Agilent 1290 Infinity TCC G1316C Verified
Warranty Coverage Extended Warranty Options Available Included
Specifications

Technical detail

Temperature Range 10°C below ambient to 100°C
Temperature Stability ± 0.05 °C
Temperature Accuracy ± 0.5 °C (with optional calibration ± 0.2 °C)
Column Capacity Up to three 30 cm columns
Internal Pre-Heater Volume 1.6 µL (standard high-pressure capillary)
Maximum Pressure Up to 1200 bar (depending on installed capillaries/valves)
Safety Features Dual leak sensors, door open sensor, electronic thermal fuse

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same specific stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1290 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical & Biotech

High-Throughput UHPLC Peptide Mapping and Stability Assays

Pharma discovery teams rely on the G1316C to maintain absolute retention time anchoring during sub-two-micron peptide separations. The ±0.05 °C stability ensures extreme peak-to-peak reproducibility across complex, high-pressure gradient sequences.

Environmental Testing

Sharp Peak Separation for Rapid Multi-Pesticide Screenings

Environmental labs use this 1200-bar compartment to drive rapid UHPLC separations of complex priority pollutants. Eliminating temperature drift ensures consistent retention windows, allowing automated data processors to accurately identify trace-level contaminants.

Food & Beverage

High-Resolution Chiral and Isomeric Content Assays

Food safety facilities deploy the 1290 column compartment to regulate spatial separation during high-pressure organic acid and lipid screenings. Precise solvent pre-heating prevents thermal peak distortion, ensuring definitive component quantifications.

Cannabis & Hemp

Fast, Continuous Cannabinoid Potency Sequences

Commercial cannabis testing hubs leverage the G1316C to achieve high peak capacity during accelerated cannabinoid fingerprinting. Running columns at elevated temperatures lowers solvent viscosity, reducing backpressure and extending analytical runtime lifetimes.

Forensic Screening

Defensible Multi-Target Toxicology Screening Matches

Crime laboratories apply this high-performance column oven to guarantee strict fluidic and thermal consistency during extensive targeted designer drug batches. The ultra-stable temperature baseline delivers the legally defensible raw data needed for judicial validation.

Weight 25 lbs
Dimensions 24 × 24 × 24 in
Condition

Refurbished

Model

G1316C

OEM

Agilent Technologies

Financing

Financing Options Available

Finance Your Laboratory Instruments with Confidence. Options that fit your budget.

GenTech Scientific, powered by Trio Capital, offers tailored financing options for your next equipment lease or instrument purchase. We make financing simple so you can obtain the equipment you need, maximize your lab’s budget, and focus on the science.

Finance today!

Need another single module?

Replacing a failed pump or expanding an existing stack? Shop our inventory of performance-verified 1290 modules and HPLC upgrades.