What you are buying
A refurbished and warrantied Agilent 7700 ICP-MS (G3281A). The system comes with autosampler, mechanical pump, chiller and data system.
Every unit we sell moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the 7700 series around a third-generation Octopole Reaction System, the ORS3, with longer and narrower rods and higher cell pressure and frequency than the ORS on the 7500 series. That redesign gives helium mode markedly better interference removal, which Agilent points to as the reason ORS3 and He mode eliminate the need for reactive cell gases in most applications. A frequency-matching 27 MHz RF generator holds the plasma stable through changing sample matrices, including organic solvents. The 7700x variant adds Agilent’s High Matrix Introduction (HMI) as a standard feature, built for routine analysis of high-matrix samples without dilution. Agilent states the 7700 series delivers the highest ion transmission across the mass range of any ICP-MS on the market at launch. MassHunter software runs the instrument, with pre-set plasma conditions and automatic lens tuning to simplify routine method setup.
What this instrument does
Rather than separating organic molecules, the Agilent 7700 ICP-MS operates as a high-temperature elemental analyzer that breaks samples down into individual atoms, ionizes them in an argon plasma, and counts target isotopes down to parts-per-trillion levels. Positioned as a standalone benchtop system paired with an external mechanical roughing pump and recirculating chiller, its primary job is to measure trace and ultra-trace metals across the periodic table. This platform executes several critical system-wide functions:
- High-Temperature Plasma Atomization: It sustains an argon plasma at 6,000–8,000 K using a frequency-matching 27 MHz RF generator, maintaining plasma stability even when analyzing volatile organic solvents or high-dissolved-solids matrices.
- ORS3 Interference Removal: It routes ions through a compact octopole collision/reaction cell pressurized with helium (and optional hydrogen), stripping away polyatomic spectral overlaps via Kinetic Energy Discrimination (KED).
- Nine-Order Dynamic Range Detection: It pairs a hyperbolic quadrupole mass filter (2–260 amu) with an orthogonal dual-mode discrete dynode detector, quantifying major elements at hundreds of ppm alongside ultra-trace contaminants at sub-ppt levels in a single run.
- Automated Setup & Maintenance Access: It automates plasma conditions and Expert AutoTune optimization in MassHunter while providing tool-free front access to the sampling cone and off-axis ion lens.
- Turnkey Automated Bundle: Supplied complete with an external mechanical roughing pump, recirculating chiller for RF coil and spray chamber thermal stability, and an automated sample introduction autosampler for unattended high-throughput sequences.
| In this stack | |
| Agilent 7700 ICP-MS G3281A | Verified |
| Autosampler | Verified |
| Mechanical Pump | Verified |
| Chiller | Verified |
| Warranty Coverage Extended Warranty Options Available | Verified |
| Workstation with preloaded software | Verified |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Mass Analyzer & Range | Hyperbolic quadrupole; 2 – 260 amu (or 1 – 260 amu) |
| Collision/Reaction Cell | 3rd Generation Octopole Reaction System (ORS3) with He mode (optional H2) |
| RF Generator & Plasma | 27 MHz frequency-matching RF generator with ShieldTorch System (6,000–8,000 K) |
| Sample Introduction | Low-flow nebulizer, Peltier-cooled spray chamber, optional HMI aerosol dilution |
| Dynamic Range | 9 orders of magnitude (sub-ppt to hundreds of ppm) |
| Sensitivity | Y (89): ≥ 160 / 240 Mcps/ppm; Tl (205): ≥ 80 / 120 Mcps/ppm |
| Vacuum System | Single split-flow turbomolecular pump paired with bundled external rotary foreline pump |
| Mainframe Dimensions & Weight | 28.7″ W × 23.4″ D × 24.4″ H (730 × 595 × 620 mm); ~254 lbs (115 kg) |
| Software Control | Agilent ICP-MS MassHunter Workstation |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same specific stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 7500 ICP/MS is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
USP <232>/<233> & ICH Q3D Elemental Impurity Screening
Pharma QC laboratories deploy this platform to monitor Class 1, 2, and 3 elemental impurities in active drug substances and excipients. Nine orders of dynamic range quantify trace heavy metals alongside major formulation elements in a single run.
EPA Method 200.8 & 6020 Trace Metals in Water and Soil
Environmental labs rely on the 7700 ICP-MS to quantify arsenic, selenium, lead, and mercury across drinking water, wastewater, and acid-digested soils. Helium collision mode eliminates polyatomic matrix interferences without mathematical corrections, ensuring rapid regulatory compliance.
Heavy Metal Contamination and Nutritional Mineral Profiling
Food safety facilities use the 7700 ICP-MS to screen infant formula, seafood, grains, and beverages for toxic arsenic, cadmium, and lead. High Matrix Introduction (HMI) aerosol dilution handles high-dissolved-solids digests cleanly without frequent cone cleaning.
State-Mandated Heavy Metals Compliance Panels
Commercial cannabis testing labs leverage this single-quadrupole ICP-MS to quantify arsenic, cadmium, lead, and mercury in flower, concentrates, and edibles. Automated Expert AutoTune and helium collision mode deliver fast, repeatable calibration curves for state compliance.
Trace Element Biomarkers and Toxicology in Biological Fluids
Clinical research labs utilize the 7700 Series to measure essential trace nutrients and toxic metal exposures in blood, serum, and urine. Low-flow sample introduction and ORS3 interference removal conserve precious sample volumes while maintaining sub-ppt sensitivity.
Direct Trace Metals in Crude Oil, Naphtha, and Fuels
Refinery laboratories apply the 7700 ICP-MS to quantify vanadium, nickel, sodium, and sulfur in crude feedstocks, kerosenes, and biofuels. Its fast frequency-matching RF generator tolerates volatile organic solvent introduction without plasma instability.
Ultra-Pure Reagent and Process Chemical Certification
Chemical and semiconductor facilities rely on the 7700 platform (especially the 7700s configuration) to certify ultra-pure water, acids, and etching reagents. Cool plasma capability and cleanroom-ready sample paths detect easily ionized alkali metals at sub-ppt levels.
Heavy Metal Poisoning and Trace Evidence Characterization
Crime and toxicology laboratories deploy the 7700 ICP-MS to confirm thallium, arsenic, and lead poisoning in post-mortem tissues and match elemental fingerprints in glass or gunshot residue. High isotope ratio precision supports legally defensible forensic comparisons.
| Weight | 350 lbs |
|---|---|
| Dimensions | 60 × 60 × 60 in |
| OEM | Agilent Technologies |
| Condition | Refurbished |
| Model | G3281A |
| Financing | Financing Options Available |
Finance Your Laboratory Instruments with Confidence. Options that fit your budget.
GenTech Scientific, powered by Trio Capital, offers tailored financing options for your next equipment lease or instrument purchase. We make financing simple so you can obtain the equipment you need, maximize your lab’s budget, and focus on the science.
Need a single part instead?
Replacing a failed nebulizer or expanding an existing instrument? Every component in this system is available individually, in stock and performance-verified.