Agilent 1290 UHPLC System Right Angle

Agilent 1290 Infinity UHPLC System




Includes:

  • Agilent 1290 Infinity UHPLC
    • Solvent Tray
    • 1290 Pump Options
    • 1290 Infinity Thermostatted Column Compartment
    • 1290 Sampler Options
    • 1290 Detector Options
  • In-House Warranty Coverage

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

Most assay, impurity, and trace-analysis methods in pharmaceutical, environmental, and food labs run on the liquid chromatography the Agilent 1290 Infinity delivers. The pump drives the mobile phase through the column at constant, reproducible flow; the sampler injects a precise volume; the column compartment holds temperature steady; the detector measures each compound as it elutes. GenTech rebuilds and tests the pump, sampler, thermostat, and detector, then verifies the stack as a system. You receive a UHPLC that arrives ready to run your methods.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent designed the 1290 Infinity around a power range, the combined envelope of flow and pressure, covering 1200 bar up to 2 milliliters per minute and 800 bar up to 5 milliliters per minute, encompassing the operating range of prior UHPLC systems on the market. The system collects data at rates up to 160 Hz with full spectral information. An integrated two-channel degasser and Jet Weaver mixer support the binary pump’s high-pressure gradient formation. The autosampler injects from vials or well plates through a flow-through design that keeps carryover low. The column compartment holds temperature within 0.15 degrees Celsius of the setpoint. A diode array detector option covers 190 to 950 nanometers for full-spectrum identification. Agilent Lab Advisor software supports diagnostics across the stack.

 

What each module does

Pump

Delivers the mobile phase at constant flow and blends the gradient. Isocratic, binary, and quaternary configurations cover everything from single-solvent assays to four-solvent method scouting. Stable flow is the basis for the retention-time reproducibility every quantitative method depends on.

Sampler

Draws a precise volume from the vial or well plate and injects it onto the column. Automated sampling runs unattended sequences overnight.

Column compartment

Holds the column at a set temperature, which fixes selectivity and retention time. Temperature control turns a method written in one lab into the same method in another.

Detector

Measures each compound as it leaves the column. The diode-array detector records full UV-visible spectra for identification and purity; variable-wavelength, fluorescence, refractive-index, and evaporative light-scattering detectors cover the analytes UV cannot see.

In this stack
Agilent TCC SL Plus G1316C Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
Agilent 1290 Infinity UHPLC Agilent 1290 Verified
Workstation loaded with software
Included
Specifications

Technical detail

Max pressure 1,200 bar to 2 mL/min, 800 bar to 5 mL/min
Data collection rate Up to 160 Hz, full spectral
Column temperature stability ±0.15°C
Pump options Isocratic, binary, quaternary
Detector options DAD, VWD, FLD, RID, ELSD
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1290 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Assay, Impurity and dissolution

The 1290 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.

Environmental

EPA HPLC methods

Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.

Food & Beverage

Additives and vitamins

The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.

Cannabis & Hemp

Cannabinoid potency

HPLC with UV detection is the reference technique for potency. The 1290 resolves the major cannabinoids for compliance and label-claim testing.

Natural Products

Botanical actives

Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.

Clinical & Forensic

Screening and drug monitoring

The 1290 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.

Chemical & Materials

Purity and additives

Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.

Method Development

Four-solvent scouting

Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.

LC/MS Front End

Proteomics, metabolomics, lipidomics

Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1290 serves as the front end feeding your MS or fraction collector.

Condition

Refurbished

Model

1290

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single module instead?

Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.