Agilent 6420 with 1200 HPLC Front End




Includes:

  • Agilent 6420 Triple Quad LC/MS
  • Agilent 1200 Front End
    • Solvent Tray
    • 1200 Degasser
    • 1200 Binary SL Pump
    • 1200 HiP ALS
    • 1200 FC/ALS Therm
    • 1200 Thermostatted Column Compartment (TCC)
  • Data System
  • Warranty Coverage

Options:

  • Module Customization
  • MS Sample Introduction
  • Mass Spec Workbench – Browse
  • Installation & Familiarization
  • Extended Warranty
  • Financing Available


15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 6420 Triple Quadrupole LC/MS with a 1200 HPLC front end. The 1200 pump and sampler separate the mixture and deliver a reproducible gradient to the source. An API-ESI source converts the eluent into gas-phase ions. The triple quadrupole isolates a precursor, fragments it, and measures the product ion for routine quantitation. GenTech rebuilds and tests the LC, the source, and the analyzer, then verifies the system end to end.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the 6420 as the entry point of the 6400 Series triple quadrupole line, with a single turbo pump, a single rough pump, and a resistive capillary. It lacks the Jet Stream ion source found on the 6460 and 6490, and the second turbo pump and updated collision cell lenses added on the 6430. The 6420 is upgradeable to a 6430. A G1948B API-ESI source ionizes the LC eluent. Agilent reports performance in signal-to-noise ratio and instrument detection limit, a statistically based measure of practical sensitivity, with autotune reaching specifications without manual adjustment. MassHunter Workstation software runs acquisition alongside compliance and method optimization tools.

 

What each module does

Liquid chromatograph

Separates the mixture and delivers a reproducible gradient to the source. The 1200 front end runs the same pumps and samplers as a standalone HPLC.

Ion source

A G1948B API-ESI source converts the liquid eluent into gas-phase ions before they cross the resistive capillary into the analyzer.

Mass analyzer

Two quadrupoles flank a collision cell. The first selects a precursor, the cell fragments it, and the second measures a product ion for routine quantitation.

Vacuum and detection

A single turbo pump and single rough pump stage the ions from atmosphere to high vacuum, then count them at the detector.

In this stack
Triple Quadrupole MS G6420A Verified
1200 HPLC Front End 1200 HPLC Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Vacuum system Single turbo pump, single rough pump
Ion source G1948B API-ESI, resistive capillary
Jet Stream Not included (6460/6490 only)
Software MassHunter
1200 HPLC Front End Agilent HPLC Front End
Max pressure 400 bar
Pump options Isocratic, binary, quaternary

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 6420 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Environmental

PFAS testing

EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.

Food & Beverage / Cannabis

Pesticides and mycotoxins

Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.

Pharmaceutical

Trace impurities and cleaning validation

Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.

Clinical & Forensic

Quantitative toxicology

Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.

Regulated Bioanalysis

GLP-grade quantitation

Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.

OEM

Agilent Technologies

Model

6420, 1200

Condition

Refurbished

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a main board instead?

Replacing a failed pump or looking to upgrade your mass spec? Every module in this system is available individually, in stock and performance-verified.