What you are buying
Environmental, forensic, and food-safety methods that identify and confirm compounds by mass run on the GC-MS the Agilent 6890N and 5973N deliver together. The 6890N separates the mixture on a capillary column; the sample crosses a heated transfer line into the 5973N; the source ionizes each compound; the quadrupole scans the mass range or watches selected ions for trace quantitation. GenTech rebuilds, plumbs, and tests the GC’s inlets, detectors, and flow path, then cleans and calibrates the MSD, and verifies the complete system end to end.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Electronic pneumatic control on the 6890N meters carrier and detector gases to 0.001 psi and 0.05 mL/min, compensating for changes in ambient pressure and temperature. The oven programs from 4 to 450 degrees Celsius across 20 ramps and 21 plateaus. The 5973N MSD attached to it runs on either a 90-liter-per-second vapor-diffusion pump or a 250-liter-per-second turbomolecular pump, with chemical ionization available only on the turbo-pump configuration. An independently heated electron-ionization source and an independently heated hyperbolic quadrupole mass filter let the source and analyzer run at separate temperatures. A triode ionization gauge tube monitors vacuum pressure. Chemical ionization hardware, where fitted, produces classical CI spectra that include molecular adduct ions, using a methane or isobutane reagent gas through a dedicated gas purifier. The detector draws up to 900 watts and weighs 194 pounds.
What each component does
Inlet
Vaporizes the sample and delivers it to the head of the column. Split/splitless handles routine concentrations; the multimode and PTV inlets add programmed temperature for trace work and thermally fragile compounds; cool on-column places the sample directly on the column for the heaviest analytes.
Column oven
Programs from 4 to 450°C across 20 ramps and 21 plateaus, with fast ramping to 75°C per minute on a 120 V oven and higher on 240 V.
Transfer line and ion source
Carries the separated compounds into the 5973N at controlled temperature. An independently heated electron-ionization source ionizes each compound, with optional chemical ionization on turbo-pump models.
Mass analyzer
An independently heated hyperbolic quadrupole filters ions by mass. It scans a full spectrum for identification or holds on selected ions for the lowest detection limits in quantitation.
| In this system | |
| Agilent 6890N GC G1530N | Verified |
| 5973N MSD G1530N | Verified |
| 7683B Autosampler G2614A | Verified |
| Optional Inlets Optional Detectors | Verified |
|
Workstation loaded with software
|
Included |
| Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system. | |
Technical detail
| Oven range | 4 to 450°C |
| Oven programming | 20 ramps, 21 plateaus |
| Fast ramp (120 V oven) | To 75°C/min |
| EPC resolution | 0.001 psi, 0.05 mL/min |
| Ionization | EI standard; CI on turbo models only |
| Vacuum pump | 90 L/sec diffusion or 250 L/sec turbo |
| Software | Loaded on workstation |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 6890N is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
| Weight | 350 lbs |
|---|---|
| Dimensions | 60 × 60 × 60 in |
| Model | 6890, 5973 |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |