Thermo TSQ 1100 Right Angle
Thermo TSQ 1100 Left Angle

Thermo TSQ Quantum Ultra Triple Quad LC/MS with Agilent 1100 HPLC Front End




Includes:

  • Thermo TSQ Quantum Ultra Triple Quad LC/MS
  • Agilent HPLC Front End
    • 1100 Solvent Tray
    • 1100 Degasser
    • 1100 Quaternary Pump
    • 1100 Autosampler
    • 1100 ALS Therm (Optional)
    • 1100 Column Compartment (Optional)
  • Two (2) Mechanical Pump
  • Data System
  • Warranty Coverage

Options:

  • MS Sample Introduction
  • N2 / Air Generator
  • Workbench
  • Wiley Registry / NIST 2023 Mass Spectral Library
  • Installation & Familiarization
  • Extended Warranty
  • Financing Available


15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Thermo Scientific TSQ Quantum Ultra mass spectrometer, paired with an Agilent 1100 HPLC front end. The 1100 pump and sampler separate the mixture and deliver a reproducible gradient to the source. The source converts the eluent into gas-phase ions. The triple quadrupole isolates a precursor, fragments it, and measures the product ion for trace-level quantitation. GenTech rebuilds and tests the LC, the source, and the analyzer, then verifies the system end to end.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Thermo Fisher built the TSQ Quantum Ultra around a HyperQuad quadrupole mass analyzer system, running highly selective reaction monitoring for added analytical selectivity over standard SRM. Standard mass range covers 10 to 1,500 Da; an extended mass range (EMR) option reaches 10 to 3,000 Da. Resolution reaches 7,500 FWHM at m/z 508 of polytyrosine, continuously adjustable to better than 0.1 Da peak width across the mass range. Mass assignment holds within 0.050 Da over 24 hours on the standard and EMR configurations, tightening to 0.025 Da on the accurate mass (AM) configuration. Optional high-field asymmetric waveform ion mobility spectrometry (FAIMS) adds a further selectivity stage ahead of the mass analyzer.

 

What each module does

Liquid chromatograph

Separates the mixture and delivers a reproducible gradient to the source. The 1100 front end runs the same pumps and samplers as a standalone HPLC.

Ion source

Converts the liquid eluent into gas-phase ions before they cross the tube/skimmer interface into the analyzer..

Mass analyzer

A HyperQuad quadrupole set flanks a collision cell. The first selects a precursor, the cell fragments it, and the second measures a product ion for trace-level quantitation.

Vacuum and detection

Stages the ions from atmosphere to high vacuum, then counts them at the detector.

In this stack
Thermo TSQ Quantum Ultra TSQ Quantum Ultra Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Analyzer HyperQuad triple quadrupole
Mass range 10 to 1,500 Da (10 to 3,000 Da, EMR)
Mass resolution 7,500 FWHM at m/z 508
Software Computer loaded with software
Mass assignment ±0.050 Da/24 hr (±0.025 Da, AM)
Optional accessory FAIMS ion mobility
HPLC front end Agilent 1100, per this listing

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The Thermo TSQ Quantum Ultra is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Environmental

PFAS testing

EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.

Food & Beverage / Cannabis

Pesticides and mycotoxins

Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.

Pharmaceutical

Trace impurities and cleaning validation

Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.

Clinical & Forensic

Quantitative toxicology

Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.

Regulated Bioanalysis

GLP-grade quantitation

Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.

Condition

Refurbished

Model

TSQ Ultra, 1100

OEM

Agilent Technologies, Thermo Scientific

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a main board instead?