The System

What you are buying

A refurbished Waters 1515 Isocratic HPLC Pump. It delivers a single-solvent mobile phase at constant, reproducible flow, built on the same core design as the 1525 binary pump.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

The 1515 is the isocratic version of the 1525 binary pump, sharing the same core components except for the second pump assembly, mixing tee, and gradient mixer that the binary pump needs for two-solvent blending. It sets flow from 0.00 to 10.00 mL/min in 0.01 mL increments, with 100-microliter pump heads, suited to columns from 2 to 4.6 millimeters in internal diameter. Flow precision holds to 0.1 percent RSD or 2 seconds standard deviation across six replicate injections, based on retention time. An integral vacuum degasser, a 1500 Series column heater running 20 to 60 degrees Celsius, and an automated seal wash are available as options, along with a manual injector for simple sample introduction. The pump runs on 120 or 240 volts at 50 or 60 hertz.

 

What each module does

Isocratic pumping

Delivers a single-solvent mobile phase at constant flow, with 100-microliter pump heads and pulse dampening for a stable baseline. Stable flow is the basis for the retention-time reproducibility every quantitative method depends on.

In this stack
Waters 1515 Isocratic Pump Waters 1515 Isocratic Pump Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Flow range 0.00 to 10.00 mL/min, 0.01 mL steps
Pump heads 100 µL
Flow precision ≤0.1% RSD or 2 sec SD
Software Included

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The Waters 1515 Isocratic HPLC Pump is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Environmental

PFAS testing

EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.

Food & Beverage / Cannabis

Pesticides and mycotoxins

Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.

Pharmaceutical

Trace impurities and cleaning validation

Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.

Clinical & Forensic

Quantitative toxicology

Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.

Regulated Bioanalysis

GLP-grade quantitation

Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.

Condition

Refurbished

Model

1515

OEM

Waters

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a main board instead?

Replacing a failed pump or looking to upgrade your HPLC? Every module in this system is available individually, in stock and performance-verified.