Agilent 1200 HPLC Autosampler Front View Right Angle
Certified Refurbished · Liquid Chromatography

Agilent 1200 Autosampler (G1329A)




The Agilent 1200 Series G1329A Autosampler is a standard automatic liquid sampler (ALS) module designed for high-performance liquid chromatography (HPLC) systems to provide precise, automated, and repeatable sample injections.

Includes:

  • Agilent 1200 Autosampler (G1329A)
    • 100 Sample tray
  •  In-House Warranty Coverage
Verified against OEM and published benchmarks
1-year warranty available
Installation and familiarization available
Financing available

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

Optimized for high-performance liquid chromatography (HPLC) workflows, the Agilent 1200 Series G1329A is a dependable automated liquid sampler built to streamline routine lab analyses. A standard variable-volume autosampler, the Agilent G1329A features a single-needle design and a standard 100 µL metering device/sample loop configuration. This module automates sample introductions to maximize throughput while delivering highly reproducible and precise injections for every run.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Both the Agilent 1100 Series autosamplers and Agilent 1200 Series autosamplers are designed for use with other modules of the Agilent 1200 Series LC system, with the HP 1050 Series, or with other LC systems if adequate remote control inputs and outputs are available. The 1200 series keeps full compatibility with existing HPLC methods and columns. Agilent designed the 1200 with more than 60 available instrument modules, covering prep-scale, standard, narrow-bore, capillary, and nanoflow LC on one platform.

What this autosampler module does

The Agilent 1200 (G1329A) Automatic Liquid Sampler (ALS) draws a precise volume from the vial and injects it onto the column. Automated sampling runs unattended sequences overnight.

In this stack
Agilent 1200 Autosampler with 100 vial tray G1329A Verified
Specifications

Technical detail

Automated Workflow Supports unattended overnight sequences and up to 99 replicate injections per vial.
Injection range 0.1 to 100 µL
Sample Capacity 100 vials (standard 1.8-mL vials)
Precision Typically <0.5% RSD of peak areas from 5 µL to 100 µL; <1% RSD from 1 µL to 5 µL
Cycle Time Fast injection cycle, typically 50 seconds
Carryover Typically <0.1%
Sample Viscosity Range .2 to 50 cp
Temperature Control Programmable, 4°C to 40°C
Safety Protocols Include built-in leak detection, safe leak handling and low-voltage maintenance zones

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Assay, Impurity and dissolution

The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.

Environmental

EPA HPLC methods

Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.

Food & Beverage

Additives and vitamins

The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.

Cannabis & Hemp

Cannabinoid potency

HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.

Natural Products

Botanical actives

Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.

Clinical & Forensic

Screening and drug monitoring

The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.

Chemical & Materials

Purity and additives

Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.

Method Development

Four-solvent scouting

Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.

LC/MS Front End

Proteomics, metabolomics, lipidomics

Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.

Model

G1329A

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single module instead?

Replacing a failed pump or expanding an existing stack? Every module in this system is available individually, in stock and performance-verified.