What you are buying
A refurbished Agilent 1200 Series G1310A isocratic pump. It delivers a single-solvent mobile phase to the column at constant, reproducible flow.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G1310A around a two-channel, dual-plunger design driven by a servo-controlled variable stroke with an active inlet valve. The pump sets flow from 0.001 to 10 mL/min in 0.001 mL/min increments, with a practical operating range of 0.2 to 10 mL/min and flow accuracy to within 1 percent or 10 microliters per minute, whichever is greater. Maximum pressure runs to 400 bar. The pump covers a recommended pH range of 1.0 to 12.5, with the caveat that solvents above pH 2.3 should avoid acids that attack stainless steel. A handheld control module enters operating parameters, stores methods, and displays the pressure profile and diagnostics. Built-in leak and pressure testing, along with Early Maintenance Feedback, supports GLP-style recordkeeping. Stainless steel, titanium, gold, ruby, sapphire, ceramic, PEEK, and PTFE make up the wetted parts. Agilent ChemStation for LC controls the pump, with an analog output of 2 millivolts per bar for pressure monitoring.
What each module does
Isocratic pumping
Delivers a single-solvent mobile phase at constant flow. Stable flow is the basis for the retention-time reproducibility every quantitative method depends on.
| In this stack | |
| Agilent 1200 Isocratic Pump G1310A | Verified |
| 1260 Vialsampler G7129A | Verified |
| 1260 Multicolumn Thermostat G7116A | Verified |
| 1260 Diode Array Detector G7115A | Verified |
|
Workstation loaded with software
|
Included |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Setable flow range | 0.001 to 10 mL/min, 0.001 mL/min steps |
| Practical flow range | 0.2 to 10 mL/min |
| Flow accuracy | ±1% or 10 µL/min, whichever is greater |
| Max pressure | 400 bar |
| pH range | 1.0 to 12.5 |
| Software | Loaded on workstation |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
| Condition | Refurbished |
|---|---|
| Model | G1310A |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.