A refurbished Agilent 1200 Series G1311A quaternary pump. It blends up to four solvents into a low-pulse gradient.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G1311A around a dual-plunger in-series pump with a servo-controlled variable stroke drive, floating plungers, and an active inlet valve. The pump sets flow from 0.001 to 10 mL/min in 0.001 mL/min increments, with a practical operating range of 0.2 to 10 mL/min. Flow precision holds to 0.07 percent RSD or 0.02 minutes standard deviation, whichever is greater, at constant room temperature, with flow accuracy within 1 percent or 10 microliters per minute. Maximum pressure runs to 400 bar at flows to 5 mL/min, dropping to 200 bar at flows to 10 mL/min. Pressure pulsation stays under 2 percent amplitude, typically under 1 percent, at 1 mL/min of isopropanol above 10 bar. Gradient delay volume runs 800 to 1,100 microliters depending on back pressure. The pump covers a recommended pH range of 1.0 to 12.5, with the caveat that solvents above pH 2.3 should avoid acids that attack stainless steel. Stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK, and PTFE make up the wetted parts. A handheld controller, Instant Pilot, or Agilent data system runs the pump, communicating over CAN, GPIB, RS-232C, and APG Remote.
What each module does
Quaternary pumping
Blends up to four solvents into a low-pulse gradient. Stable, low-pulse flow is the basis for the retention-time reproducibility every quantitative method depends on. Rated to 400 bar.
| In this listing | |
| Agilent 1200 Quaternary Pump G1311A | Verified |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Setable flow range | 0.001 to 10 mL/min, 0.001 mL/min steps |
| Max pressure | 400 bar to 5 mL/min, 200 bar to 10 mL/min |
| Flow precision | 0.07% RSD or ≤0.02 min SD |
| Delay volume | 800 to 1,100 µL |
| pH range | 1.0 to 12.5 |
| Software | Loaded on workstation |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
| Condition | Refurbished |
|---|---|
| Model | G1311A |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.