Agilent 1260 VWD SL Left Angle
Agilent 1260 VWD SL Right Angle

Agilent 1260 Variable Wavelength Detector (VWD) VL




Includes:

  • Agilent 1260 Variable Wavelength Detector (VWD) VL
    • Standard flow cell
  • In-House Warranty Coverage

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

An Agilent 1260 Infinity G1314B VWD VL, a variable wavelength detector. It measures absorbance at selected wavelengths, built for standard HPLC data rates rather than the faster fast-HPLC rate of the VL+ variant.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the G1314B VWD VL as a double-beam photometer with a deuterium lamp, covering 190 to 600 nanometers. It reaches a maximum data rate of 13 Hz, suited to standard HPLC rather than the faster 55 Hz the VL+ variant (G1314C) reaches for fast HPLC. Noise runs under 0.5 x 10-5 AU at 230 nanometers, with drift around 3 x 10-4 AU per hour at the same wavelength. Optional flow cell cartridges cover standard (10-millimeter path, 14 microliters), high-pressure, micro (5-millimeter path, 1 microliter), and semi-micro (6-millimeter path, 5 microliters) configurations. A built-in holmium oxide filter verifies wavelength accuracy without an external standard. The detector weighs 11 kilograms and draws 220 VA.

 

What each module does

Variable wavelength detection

Measures absorbance at selected wavelengths, over a range of roughly 190 to 600 nm, at data rates up to 13 Hz. It drops into a compatible 1260 Infinity HPLC stack under OpenLab CDS or ChemStation.

In this stack
Agilent 1260 VWD VL G1314B Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Detection type Double-beam photometer, deuterium lamp
Wavelength range 190 to 600 nm
Max data rate 13 Hz (standard HPLC)
Noise / drift 0.5 x 10-5 AU / ~3 x 10-4 AU/hr at 230 nm
Wavelength verification Built-in holmium oxide filter
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1260 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Assay, Impurity and dissolution

The 1260 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.

Environmental

EPA HPLC methods

Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.

Food & Beverage

Additives and vitamins

The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.

Cannabis & Hemp

Cannabinoid potency

HPLC with UV detection is the reference technique for potency. The 1260 resolves the major cannabinoids for compliance and label-claim testing.

Natural Products

Botanical actives

Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.

Clinical & Forensic

Screening and drug monitoring

The 1260 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.

Chemical & Materials

Purity and additives

Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.

Method Development

Four-solvent scouting

Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.

LC/MS Front End

Proteomics, metabolomics, lipidomics

Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.

Condition

Refurbished

Model

G1314B

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single module instead?