What you are buying
A refurbished Agilent 1260 Infinity II G1364F analytical-scale fraction collector. It collects separated fractions by time, peak, or threshold, optimized for nanogram-to-milligram scale purification.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this module
Agilent built the G1364F around four operating modes. Discrete fractions, the default, diverts flow to waste while moving between vessel positions. Continuous flow, available only with deep well plates, moves between positions without diverting the flow. Needle into location pushes the needle into the vessel for capped vials, tubes, and well plates with closing mats. Droplet setup mode moves the needle to the bottom of the well, then slowly upward as the fraction collects, to avoid trapping bubbles in small fractions. Maximum system flow reaches 10 milliliters per minute, with a maximum collection volume of about 20 milliliters using a 30-by-48-millimeter tube. Up to three fraction collectors can run in parallel, plus one recovery collector. A built-in fraction delay sensor calibrates delay automatically. Four preconfigured capillary kits minimize peak dispersion. The unit weighs 13.5 kilograms without a thermostat and measures 200 by 345 by 440 millimeters.
What this module does
Fraction collection
Gathers purified fractions from an analytical-scale separation, triggered by time, by a peak threshold, or by droplet-level collection that avoids bubbles in small fractions.
| In this listing | |
| Agilent 1260 Infinity II Fraction Collector G1364F | Verified |
| In-House Warranty Coverage | Included |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Operating modes | Discrete, continuous flow, needle-into-location, droplet> |
| Max system flow | 10 mL/min |
| Max collection volume | ~20 mL (30 x 48 mm tube) |
| Clustering | Up to 3 units in parallel, plus 1 recovery unit |
| Delay calibration | Built-in sensor, automatic |
| Software | Loaded on workstation |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1260 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1260 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1260 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1260 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
| OEM | Agilent Technologies |
|---|---|
| Model | G1364F |
| Condition | Refurbished |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need another single module?
Replacing a failed pump? Expanding an existing stack? Every module we carry is available individually, in stock, and performance-verified.