15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent G1323A handheld control module. It runs local control and monitoring for a single 1100 Series module or an entire stack over the CAN bus.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this controller
Agilent built the G1323A as a handheld control module for local operation of a single module or an entire 1100 Series system over the CAN bus. The G1323A version controls a defined set of modules: the diode array detector, the fluorescence detector, the variable wavelength detector, the quaternary, binary, and isocratic pumps, the thermostatted column compartment, and the autosampler or thermostatted autosampler. It does not control the multiple wavelength detector or the refractive index detector; those require the G1323B version instead, which shares the same interface and functionality. Method protection guards stored methods against accidental keyboard changes. PC cards store and transfer methods and sequences between systems. Self-updating logs track operations and error events.
What this component does
Handheld control
Provides local control and status monitoring for a single 1100 Series module or a complete stack, connected over the CAN bus.
| In this listing | |
| Agilent Handheld Control Module G1323A | Verified |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Connection | CAN bus |
| Supported detectors | DAD (G1315A), FLD (G1321A), VWD (G1314A) |
| Supported pumps | Quaternary, binary, isocratic (G1311A/G1312A/G1310A) |
| Supported modules | TCC (G1316A), autosampler, thermostatted autosampler |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1100 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1100 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1100 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1100 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1100 serves as the front end feeding your MS or fraction collector.
| Model | G1323A |
|---|---|
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a single HPLC module?
Replacing a failed pump or expanding an existing stack? Every module in inventory is available individually, in stock and performance-verified.







