15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
Environmental, forensic, and food-safety methods that identify and confirm compounds by mass run on the GC-MS/MS the Agilent 7000 Series delivers. The 7890B gas chromatograph separates the mixture; the sample crosses a heated transfer line into the source; the source ionizes each compound; the triple quadrupole isolates a precursor, fragments it, and measures the product ions for selective quantitation. The 7693 autosampler runs unattended sequences from vial to injection. GenTech rebuilds and tests the GC, the autosampler, the source, and the analyzer, then verifies the system end to end.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
The Agilent 7000 Series Triple Quad requires pairing with a high-performance 7890 GC; Agilent does not sell the MS/MS analyzer as a standalone unit for other GC brands. A hexapole collision cell, blanketed with a combination of nitrogen and helium gas, is unique to the 7000/7010 Series among triple quadrupole GC/MS systems, improving ion fragmentation ahead of detection. The standard ion source runs electron ionization with a noncoated, proprietary inert design; optional positive and negative chemical ionization extend the range of compounds the instrument can confirm. Mass range covers 10 to 1,050 m/z, with dual filaments for EI and electron energy from 10 to 300 eV. Agilent rates sensitivity using instrument detection limit rather than signal-to-noise, an eight-injection verification the company considers more representative than a single-injection S/N measurement, particularly at the very low background levels MS/MS methods typically show. MassHunter Workstation software handles quantitative and qualitative data analysis.
What each component does
Gas chromatograph
Vaporizes the sample and delivers it to the head of the column. Split/splitless handles routine concentrations; the multimode and Separates the mixture on a capillary column under programmed temperature and electronic pneumatic control. The 7890B front end runs the same inlets, detectors, and Capillary Flow Technology as a standalone GC.
Autosampler
The 7693 draws a precise volume from a vial and injects it onto the column, running unattended sequences without an operator.
Transfer line and ion source
Carries the separated compounds into the mass spectrometer at controlled temperature, with no cold spots to lose heavy analytes. Electron ionization produces the reproducible, library-searchable spectra environmental and forensic methods rely on; chemical ionization preserves the molecular ion for confirmation.
Mass analyzer
Two quadrupoles flank a nitrogen/helium-blanketed hexapole collision cell. The first selects a precursor ion, the cell fragments it, and the second measures a product ion, which gives the selectivity that trace quantitation in complex matrices demands.
| In this system | |
| Agilent 7890B 7890B | Verified |
| 7000 Series Triple Quad G7012A | Verified |
| 7683B Autosampler G2614A | Verified |
| Optional Inlets Optional Detectors | Verified |
|
Workstation loaded with software
|
Included |
| Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system. | |
Technical detail
| GC platform | 7890B (paired with 7000 Series) |
| Autosampler | 7693, vial-based injection |
| Mass range | 10 to 1,050 m/z |
| Ionization | EI standard; PCI, NCI optional |
| Collision cell | Hexapole, N2/He-blanketed (unique to this series) |
| Software | Loaded on workstation |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 7890B with 7000C is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
| Condition | Refurbished |
|---|---|
| Model | 7000, 7890, 7693 |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Put the financing content and link here.
Need a single detector instead?
Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.