9000-7697
Agilent Intuvo 9000 GC System, Column
FID SplitSplitless, Agilent Intuvo 9000 GC
Flame Ionization Detector (FID), on Agilent Intuvo 9000 GC
Flame Ionization Detector (FID), SplitSplitless, on Agilent Intuvo 9000 GC System
Certified Refurbished · Gas Chromatography

Agilent Intuvo 9000 GC with 7697A Headspace Sampler




Includes:

  • Agilent Intuvo 9000 GC System
    • Split/Splitless Inlet
    • Dual Flame Ionization Detectors (FID)
  • Agilent 7697A Headspace
  • Data System
  • Warranty Coverage
Verified against OEM and published benchmarks
1-year warranty available
Installation and familiarization available
Financing available

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

High-throughput petrochemical, food-safety, and environmental methods run on the fast, low-maintenance separations the Intuvo 9000 delivers. A Guard Chip protects the flow path from contamination and eliminates the ferrule connections and column clipping older GC platforms require. The direct-heated oven ramps from 30 to 450°C at up to 250°C per minute. Ballistic column heating cuts cycle time between runs. GenTech rebuilds, plumbs, and tests the flow path chips, detectors, and oven, then verifies the instrument against reference standards. You receive an Intuvo that arrives verified and ready to run your methods.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent positions the Intuvo 9000 as a step beyond conventional GC architecture. A Guard Chip, a single-use consumable, seals the flow path and protects downstream components from contamination; Agilent’s no-trim columns click into place without ferrules or a wrench. Smart Keys attached to the flow path components identify configuration and column age and load default method parameters automatically. Built-in intelligence tracks more than 100 instrument parameters in real time and walks an operator through self-guided troubleshooting and maintenance. Agilent cites 30 to 450°C oven ramps at up to 250°C per minute from direct, ballistic column heating, faster and more reproducible than a conventional convection oven. Agilent pairs the Intuvo 9000 with its 5977, 7000, and 7010 mass spectrometers for GC-MS configurations.

What each component does

Guard Chip and flow path

A single-use Guard Chip seals the flow path and protects downstream components from contamination. Ferrule-free, click-and-run connections let an operator swap a column in under a minute without tools or leak checks.

Column oven

Direct, ballistic heating replaces a conventional convection oven and ramps from 30 to 450°C at up to 250°C per minute. Faster, more repeatable ramps shorten cycle time between injections.

Inlet and detector chips

Inlets and detectors install as planar chip modules instead of separately plumbed hardware. A chip change replaces the manual reconfiguration a conventional GC needs to switch detection chemistry.

Smart Keys

Smart Keys attached to flow path components identify the installed configuration and column age and load the default method parameters for that setup, which cuts setup error at changeover.

Built-in intelligence

Onboard diagnostics track more than 100 instrument parameters in real time and walk an operator through self-guided maintenance and troubleshooting instead of a service call.

In this system
Agilent Intuvo 9000 GC G4581A Verified
Detectors Dual FID Verified
Inlet Split/Splitless (S/S) Verified
Agilent 7697A Headspace Sampler G4557A Verified
Workstation with preloaded software Included
Specifications

Technical detail

Oven range 30 to 450°C
Max ramp rate 250°C/min, direct ballistic heating
Column change Under 1 minute, no ferrules
Diagnostics 100+ parameters monitored in real time
MS compatibility Agilent 5977, 7000, 7010
Condition Certified Refurbished
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The Intuvo 9000 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Petrochemical

Hydrocarbons and fuels

Food & Beverage / Chemical

Solvents and fatty acids

Petrochemical / Semiconductor / Chemical

Permanent and fixed gases

Environmental / Food & Beverage

Pesticides and halogenated compounds

Environmental / Food & Beverage

Nitrogen and phosphorus pesticides

Petrochemical / Environmental

Sulfur and phosphorus compounds

Environmental

Volatiles and semivolatiles

Pharmaceutical / Cannabis

Residual solvents confirmation

Food & Beverage / Cannabis

Pesticides and terpenes

Model

9000, 7697A

OEM

Agilent Technologies

Condition

Refurbished

Financing

Financing Options Available

Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS system

Download

This cannabis testing application note is for the Agilent 7697A Headspace Sampler with the Agilent Intuvo 9000 system.

Financing Options Available.  Finance Builder.

Need a single detector instead?

Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.

15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

High-throughput petrochemical, food-safety, and environmental methods run on the fast, low-maintenance separations the Intuvo 9000 delivers. A Guard Chip protects the flow path from contamination and eliminates the ferrule connections and column clipping older GC platforms require. The direct-heated oven ramps from 30 to 450°C at up to 250°C per minute. Ballistic column heating cuts cycle time between runs. GenTech rebuilds, plumbs, and tests the flow path chips, detectors, and oven, then verifies the instrument against reference standards. You receive an Intuvo that arrives verified and ready to run your methods.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent positions the Intuvo 9000 as a step beyond conventional GC architecture. A Guard Chip, a single-use consumable, seals the flow path and protects downstream components from contamination; Agilent’s no-trim columns click into place without ferrules or a wrench. Smart Keys attached to the flow path components identify configuration and column age and load default method parameters automatically. Built-in intelligence tracks more than 100 instrument parameters in real time and walks an operator through self-guided troubleshooting and maintenance. Agilent cites 30 to 450°C oven ramps at up to 250°C per minute from direct, ballistic column heating, faster and more reproducible than a conventional convection oven. Agilent pairs the Intuvo 9000 with its 5977, 7000, and 7010 mass spectrometers for GC-MS configurations.

What each component does

Guard Chip and flow path

A single-use Guard Chip seals the flow path and protects downstream components from contamination. Ferrule-free, click-and-run connections let an operator swap a column in under a minute without tools or leak checks.

Column oven

Direct, ballistic heating replaces a conventional convection oven and ramps from 30 to 450°C at up to 250°C per minute. Faster, more repeatable ramps shorten cycle time between injections.

Inlet and detector chips

Inlets and detectors install as planar chip modules instead of separately plumbed hardware. A chip change replaces the manual reconfiguration a conventional GC needs to switch detection chemistry.

Smart Keys

Smart Keys attached to flow path components identify the installed configuration and column age and load the default method parameters for that setup, which cuts setup error at changeover.

Built-in intelligence

Onboard diagnostics track more than 100 instrument parameters in real time and walk an operator through self-guided maintenance and troubleshooting instead of a service call.

In this system
Agilent Intuvo 9000 GC G4581A Verified
Oven range 30 to 450°C Verified
7683B Autosampler G2614A Verified
Optional Inlets Optional Detectors Verified
Workstation loaded with software
Included
Specifications

Technical detail

Oven range 30 to 450°C
Max ramp rate 250°C/min, direct ballistic heating
Column change Under 1 minute, no ferrules
Diagnostics 100+ parameters monitored in real time
MS compatibility Agilent 5977, 7000, 7010
Condition Certified Refurbished
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The Intuvo 9000 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Petrochemical

Hydrocarbons and fuels

Food & Beverage / Chemical

Solvents and fatty acids

Petrochemical / Semiconductor / Chemical

Permanent and fixed gases

Environmental / Food & Beverage

Pesticides and halogenated compounds

Environmental / Food & Beverage

Nitrogen and phosphorus pesticides

Petrochemical / Environmental

Sulfur and phosphorus compounds

Environmental

Volatiles and semivolatiles

Pharmaceutical / Cannabis

Residual solvents confirmation

Food & Beverage / Cannabis

Pesticides and terpenes

Model

9000, 7697A

OEM

Agilent Technologies

Condition

Refurbished

Financing

Financing Options Available

Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS system

Download

This cannabis testing application note is for the Agilent 7697A Headspace Sampler with the Agilent Intuvo 9000 system.

Financing Options Available.  Finance Builder.

Need a single detector instead?

Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.

Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS system

Download

This cannabis testing application note is for the Agilent 7697A Headspace Sampler with the Agilent Intuvo 9000 system.