Shimadzu 8060 with Front End Left Angle
Shimadzu 8060 with Front End Right Angle

Shimadzu 8060 Triple Quad LC/MS with Nexera HPLC Front End

Includes:

  • Shimadzu 8060 LC/MS
  • Shimadzu Nexera HPLC Front End
    • System Controller
    • Three DGU-20A5R CL Degasser
    • Two-LC-30AD CL Pumps
    • SIL-30AC MP CL Autosampler
    • CTO-20AC CL Column Oven
    • CBM-20A CL
  • Mechanical Pump
  • Data System
  • Warranty Coverage

Options:

  • MS Sample Introduction
  • Generator
  • Air Compressor
  • Workbench
  • Wiley Registry / NIST 2023 Mass Spectral Library
  • Installation & Familiarization
  • Extended Warranty
  • Financing Available

15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Shimadzu LCMS-8060 with a Nexera UHPLC front end. The Nexera pump and autosampler separate the mixture and deliver a reproducible gradient to the source. The 8060’s ion source converts the eluent into gas-phase ions. The triple quadrupole isolates a precursor, fragments it, and measures the product ion at trace levels. GenTech rebuilds and tests the LC, the source, and the analyzer, then verifies the system end to end.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Shimadzu positions the LCMS-8060 as the flagship of its triple quadrupole line, built on the same 30,000 u per second scan speed and 5 millisecond polarity switching as the LCMS-8050. An optimized ion guide, UF-Qarray, and updated ion transport optics raise ion sampling efficiency and focusing, which Shimadzu reports as roughly three times the sensitivity of the LCMS-8050. A UFsweeper III collision cell, filled with argon gas, reaches dwell times of 0.8 milliseconds per MRM transition. Shimadzu’s Nexera pumps reach up to 130 megapascals, or 1,300 bar, with a flow range from 0.1 microliters to 10 milliliters per minute and flow accuracy within 1 percent or 2 microliters per minute, whichever is greater. A parallel dual micro-plunger design, each plunger holding 10 microliters, keeps pulsation low and the baseline stable. The SIL-30AC autosampler shares the same 130-megapascal pressure rating and injects a sample in as little as 10 seconds. Auto-diagnostic and auto-recovery functions detect abnormal pressure fluctuations and respond automatically, limiting sample loss and downtime.

 

What each module does

Nexera pump and autosampler

Delivers a reproducible gradient at up to 1,300 bar and injects a precise volume from a vial, with a SIL-30AC autosampler capable of a 10-second injection cycle.

Ion source

Converts the liquid eluent into gas-phase ions ahead of the analyzer, handling the polarity switching needed for simultaneous positive and negative ion methods.

Mass analyzer

Two quadrupoles flank a UFsweeper III argon-filled collision cell. The first selects a precursor, the cell fragments it, and the second measures a product ion, running MS/MS scans and MRM measurements in the same acquisition.

Vacuum and detection

Stages the ions from atmosphere to high vacuum, then counts them at the detector.

In this stack
Triple Quadrupole MS LCMS-8060 Verified
Nexera HPLC Front End Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Nexera HPLC Front End
Max pressure 130 MPa (1,300 bar)
Flow range 0.1 µL/min to 10 mL/min
Autosampler cycle As fast as 10 sec (SIL-30AC)
Shimadzu LCMS-8060y
Scan speed Up to 30,000 u/sec
Polarity switching 5 msec
Collision cell UFsweeper III, argon-filled, 0.8 ms/MRM dwell

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The Shimadzu 8060 Triple Quad LC/MS with Nexera HPLC Front End is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Environmental

PFAS testing

EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.

Food & Beverage / Cannabis

Pesticides and mycotoxins

Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.

Pharmaceutical

Trace impurities and cleaning validation

Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.

Clinical & Forensic

Quantitative toxicology

Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.

Regulated Bioanalysis

GLP-grade quantitation

Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.

Weight 500 lbs
Dimensions 60 × 60 × 60 in
Condition

Refurbished

Model

8060

OEM

Shimadzu

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a main board instead?

Replacing a failed pump or looking to upgrade your mass spec? Every module in this system is available individually, in stock and performance-verified.