An Agilent 1200 Series G1316B TCC SL column thermostat. It holds the column at a set temperature up to 100°C, twenty degrees higher than the base G1316A, with hardware tuned to reduce dispersion at low flow rates.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G1316B SL to reach 100 degrees Celsius with Peltier heating and cooling, twenty degrees higher than the base G1316A’s 80-degree ceiling. Two independently programmable heat exchangers hold internal volume to just 3 and 6 microliters, which keeps dead volume low. The SL adds heating and cooling devices tuned for low flow rates, reducing the dispersion risk that low-flow methods are prone to. An optional kit supplements the SL with a small heat exchanger at 1.6 microliters of delay volume, cutting dispersion further for demanding low-dispersion methods. The compartment holds up to three 30-centimeter columns. An optional column switching valve, available on both the G1316A and the G1316B SL, adds automated column selection. The TCC runs as a standalone module or as part of a complete 1200 Series stack, controlled through Agilent Lab Advisor software.
What each module does
High-temperature column thermostat
Holds the column at a set temperature up to 100°C, with low-dispersion hardware for low-flow methods that the base G1316A does not include.
| In this stack | |
| Agilent TCC SL G1316B | Verified |
| 1260 Vialsampler G7129A | Verified |
| 1260 Multicolumn Thermostat G7116A | Verified |
| 1260 Diode Array Detector G7115A | Verified |
|
Workstation loaded with software
|
Included |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Temperature range | 10°C below ambient to 100°C |
| Heat exchanger volume | 3 µL and 6 µL, independently programmable |
| Low-flow option | Optional 1.6 µL heat exchanger kit |
| Column capacity | Up to three 30 cm columns |
| Optional valve | Column switching (G1316A, G1316B SL) |
| Software | Loaded on workstation |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
| Condition | Refurbished |
|---|---|
| Model | G1316B |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.