Agilent 1260 HIP Autosampler Sample Tray
Agilent 1260 HIP Autosampler Back View
Certified Refurbished · Liquid Chromatography

Agilent 1260 Infinity HPLC Autosampler

$7,999.00




The Agilent G1367E High-Performance Autosampler is a premium, high-throughput sampling module designed for demanding UHPLC and LC-MS configurations.

Includes:

  • Agilent 1260 Infinity HiP Autosampler (G1367E)
    • CAN Cable
  • In-House Warranty Coverage
Verified against OEM and published benchmarks
1-year warranty available
Installation and familiarization available
Financing available

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 1260 Infinity HiP Autosampler (G1367E).  Engineered for ultimate precision, rapid cycle times, and modern column technology, the G1367E utilizes Agilent’s sophisticated flow-through fluidic design to deliver ultra-low carryover—making it a staple for high-sensitivity applications and automated screening workflows.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

According to official Agilent product literature, the 1260 Infinity High-Performance Autosampler (Model G1367E) is engineered specifically for laboratories demanding high-throughput automation combined with ultimate chromatographic performance. Agilent highlights the module’s specialized flow-through design as the benchmark for ultra-low carryover, ensuring that the sample loop and needle are continuously flushed by the mobile phase during the analytical run. The OEM positions this module as an essential asset for high-sensitivity liquid chromatography and LC-MS applications, noting its ability to execute rapid, precise injection cycles under 21 seconds at operating pressures up to 600 bar. Furthermore, Agilent emphasizes the unit’s flexible, robotic sample handling system, which seamlessly switches between standard vial trays and high-density 96- or 384-well plates to maximize unattended laboratory productivity.

What this module does

Liquid injection

Draws a precise volume from the vial or well and injects it onto the column using a specialized, low-carryover flow-through design. An advanced X-Z-Theta transport mechanism positions the robotic sampling arm accurately over any vial or high-density well plate.

Automated sequencing

Runs high-throughput, unattended sequences using a dual-plate tray design that accommodates up to two standard 96-well or 384-well plates, plus a fixed 10-vial auxiliary tray for standard 2-mL vials. Removable trays are also available for standard vials, microvials, or Eppendorf tubes.

In this stack
Agilent 1260 HiP Autosampler G1367E Verified
Specifications

Technical detail

Maximum Operating Pressure 600 bar (8,700 psi)
Injection Range 0.1 to 100 µL (Standard analytical head)
Injection Precision <0.25% RSD (from 5 – 40 µL)
Carryover Typically < 0.004%
Sample Capacity 2 x Well Plates + 10 auxiliary 2-mL vials

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1260 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Assay, Impurity and dissolution

The 1260 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.

Environmental

EPA HPLC methods

Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.

Food & Beverage

Additives and vitamins

The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.

Cannabis & Hemp

Cannabinoid potency

HPLC with UV detection is the reference technique for potency. The 1260 resolves the major cannabinoids for compliance and label-claim testing.

Natural Products

Botanical actives

Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.

Clinical & Forensic

Screening and drug monitoring

The 1260 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.

Chemical & Materials

Purity and additives

Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.

Method Development

Four-solvent scouting

Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.

LC/MS Front End

Proteomics, metabolomics, lipidomics

Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.

Weight 54 lbs
Dimensions 11 × 18 × 22 in
Condition

Refurbished

Model

G1367E

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single module instead?

Replacing a failed pump or expanding an existing stack? Every module in this system is available individually, in stock and performance-verified.