A refurbished Agilent 1290 Infinity G1330B Autosampler Thermostat, with warranty coverage. It holds samples at a set temperature in the autosampler tray, protecting temperature-sensitive samples before injection.
Every unit we sell moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G1330B around the same Peltier-controlled heat exchangers as the G1330A, with a settable temperature range of 4 to 40 degrees Celsius in 1-degree increments. Temperature accuracy holds to between -1 and +4 degrees Celsius at a 4-degree setpoint when ambient temperature stays under 25 degrees Celsius and humidity under 50 percent, widening to +5 degrees Celsius above that ambient threshold. Agilent highlights this module for its advanced solid-state Peltier cooling and heating architecture, which sits beneath the main autosampler to regulate the sample compartment without the need for noisy or maintenance-heavy compressors. By continuously circulating dehumidified, temperature-controlled air across the sample vials or microplates, the G1330B completely eliminates condensation and temperature gradients. The thermostat pairs with the G1389A, G1367A, or G2260A autosampler module over a control cable, with each module keeping its own power supply. It works with other 1200 or 1290 Infinity Series modules, or with other LC systems that have adequate remote control inputs and outputs, controlled from the Agilent Instant Pilot or from Agilent’s own LC control software. The thermostatted sample tray holds 100 1.8-milliliter vials, or two well plates plus 10 1.8-milliliter vials. The unit operates up to 2000 meters altitude and tolerates humidity under 95 percent at 40 degrees Celsius without condensing. It measures 13.5 by 17 by 5.5 inches and weighs 20.7 kilograms.
What this module does
Rather than a standalone sample tray, the Agilent G1330B is a dedicated external thermal regulation module that docks directly with an analytical autosampler stack (such as the G1329B, G1367E, or G4226A). Positioned immediately below the host autosampler compartment, its primary job is to cool or heat the sample environment to protect volatile or unstable compounds. This process executes several critical system-wide functions:
- Prevents Analyte Degradation: It cools the sample deck down to 4 °C, effectively slowing down enzymatic breakdown or thermal degradation of delicate biological samples waiting in the queue.
- Eliminates Condensation Build-Up: It features a built-in condensation handling channel that routes moisture away from the electronics, ensuring a dry, safe environment inside the sample chamber.
- Minimizes Volatilization Losses: It regulates ambient conditions to prevent the evaporation of low-boiling-point solvents, preserving exact sample concentrations across extended runtime sequences.
- Maintains Thermal Uniformity: It leverages a high-capacity internal fan assembly to evenly distribute conditioned air across all vials or microtiter well-plates, eliminating localized warm spots.
Connects to a G1389A, G1367A, or G2260A autosampler module over a control cable, each keeping its own power supply.
| In this listing | |
| Agilent 1290 Autosampler Thermostat G1330B | Verified |
| Warranty Coverage Extended Warranty Options Available | Included |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Temperature Operating Range | 4 to 40°C (adjustable in 1°C increments) |
| Temperature accuracy | -1 to +4°C at specified ambient conditions |
| Cooling/Heating Principle | Solid-state electronic Peltier thermostatic regulation |
| Refrigerant Type | None (CFC-free, completely compressorless design) |
| Air Circulation | High-volume internal air fan with automated condensation drainage |
| Compatibility | Agilent 1100, 1200, 1260, and 1290 analytical autosamplers |
| Interface Connections | Specialized direct-ribbon cable interface to host autosampler |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same specific stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1290 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Cold-Chain Preservation of Proteins and Biologics
Pharma discovery groups rely on the G1330B to keep delicate proteins, peptides, and monoclonal antibodies chilled at a steady 4 °C. Preventing ambient degradation guarantees accurate quantitative tracking across massive, multi-day auto-injection arrays.
Volatility Control in High-Throughput Extract Queues
Environmental labs deploy this thermostat to prevent the loss of volatile organic compounds from sample trays during extended analytical runs. Active temperature control eliminates evaporation risks, ensuring highly reproducible calibration data over time.
Degradation Prevention for Sensitive Vitamin Assays
Food safety facilities use the 1290 thermostat to isolate and preserve temperature-sensitive nutritional components like vitamins and natural enzymes. Keeping the sample deck cool prevents chemical breakdown, ensuring accurate, true-to-source quality metrics.
Stable Preservation of Viscous and Volatile Terpenes
Commercial cannabis testing centers leverage this Peltier cooling module to maintain sample stability during dense, back-to-back terpene runs. Restricting ambient heat protects volatile aromatic fractions, keeping customer potency profiles uncompromised.
Secure Stabilization of Unstable Biological Toxicology Vials
Crime laboratories apply this autosampler thermostat to guarantee structural compound stability during extensive forensic blood and tissue toxicology sequences. Maintaining stable, chilled conditions protects fragile target metabolites from ambient degradation before injection.
| Weight | 46 lbs |
|---|---|
| Dimensions | 24 × 24 × 24 in |
| Condition | Refurbished |
| Model | G1330B |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Finance Your Laboratory Instruments with Confidence. Options that fit your budget.
GenTech Scientific, powered by Trio Capital, offers tailored financing options for your next equipment lease or instrument purchase. We make financing simple so you can obtain the equipment you need, maximize your lab’s budget, and focus on the science.
Need another single module?
Replacing a failed pump or expanding an existing stack? Shop our inventory of performance-verified 1290 modules and HPLC upgrades.