15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 5973A single-quadrupole mass selective detector. It ionizes each compound as it elutes from the GC; the quadrupole then measures the mass spectrum. Electron ionization gives library-searchable spectra for identification; selected-ion monitoring drives trace quantitation.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent designed the 5973A as a stand-alone capillary GC detector built for the HP and Agilent 6890 series gas chromatograph. An independently heated electron-ionization source and an independently heated hyperbolic quadrupole mass filter give the analyzer its own temperature control, separate from the GC oven. A high-energy dynode electron multiplier detects the ions. A rotary vane foreline pump backs either a 90 L/sec diffusion or a 250 L/sec turbomolecular high-vacuum pump. The 5973A scans a mass range of 10 to 800 amu. A local control panel lets an operator run a tune, a method, or a sequence directly at the instrument.
What each component does
Ion source
Ionizes each compound as it elutes from the GC. Electron ionization produces reproducible, library-searchable spectra.
Quadrupole
Filters ions by mass. It scans a full spectrum for identification or holds on selected ions for the lowest detection limits.
Detector and vacuum
Counts the ions and stages the analyzer to high vacuum for stable, sensitive operation.
| In this system | |
| Agilent 5973A MSD G2577A | Verified |
| Diffusion Pump or optional Turbo Pump | Verified |
| Mechanical Pump | Verified |
| Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system. | |
Technical detail
| Ionization | Electron ionization (EI) |
| Mass range | 10 to 800 amu |
| Ion source temperature | Independently heated |
| Quadrupole | Independently heated, hyperbolic |
| Detector | High-energy dynode (HED) electron multiplier |
| Condition | Certified Refurbished |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 5975C MSD is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
| Model | 5973A |
|---|---|
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a single detector instead?
Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.





















