Agilent 7697A Headspace Sampler Left Angle View
Agilent 7697A Headspace Sample View

Agilent 7697A Headspace Sampler




Included:

  • Agilent 7697A Headspace Sampler
    • 111 Sample Configuration
  • Warranty Coverage

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 7697A Headspace, a headspace sampler. It samples the vapor above the sample for volatile analysis; it runs unattended sequences.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the 7697A on the same architecture as its 7890 GC and 7693A automatic liquid sampler. An inert sample pathway carries the vapor to the GC without analyte loss or degradation. An automatic leak check confirms each vial is sealed before the run starts. The sampler stores up to 32 user-defined headspace methods, plus five presets, and up to 9 sequences. An operator can run it standalone from a chemical-resistant keypad or over LAN through OpenLab CDS ChemStation, OpenLab CDS EZChrom, or MSD ChemStation. Independent control of vial pressurization and column head pressure keeps sample transfer free of backpressure. Priority sample positions accommodate a late-arriving sample without breaking the sequence. Barometric pressure compensation holds results consistent across instruments and labs. The 7697A runs on hydrogen as a carrier gas. Sleep and Wake modes cut gas and power use between runs.

What each component does

Vapor sampling

Samples the vapor above the sample for volatile analysis, without carrying the liquid or solid matrix into the GC.

Automated sequencing

Runs overnight sequences without an operator, working through the loaded tray on its own schedule.

In this system
Agilent 7697A Headspace G4557A Verified
Oven range 4 to 450°C Verified
7683B Autosampler G2614A Verified
Optional Inlets Optional Detectors Verified
Workstation loaded with software
Included
Specifications

Technical detail

Vial capacity 12 or 111 vials
Stored methods 32 user-defined, plus 5 presets
Stored sequences Up to 9
Carrier gas Compatible with hydrogen
Power modes Sleep and Wake
Condition Certified Refurbished
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 7697A is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Petrochemical

Hydrocarbons and fuels

Food & Beverage / Chemical

Solvents and fatty acids

Petrochemical / Semiconductor / Chemical

Permanent and fixed gases

Environmental / Food & Beverage

Pesticides and halogenated compounds

Environmental / Food & Beverage

Nitrogen and phosphorus pesticides

Petrochemical / Environmental

Sulfur and phosphorus compounds

Environmental

Volatiles and semivolatiles

Pharmaceutical / Cannabis

Residual solvents confirmation

Food & Beverage / Cannabis

Pesticides and terpenes

Condition

Refurbished

Model

7697A

OEM

Agilent Technologies

Financing

Financing Options Available

Put the financing content and link here.

Need a single detector instead?

Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.

15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 7697A Headspace, a headspace sampler. It samples the vapor above the sample for volatile analysis; it runs unattended sequences.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the 7697A on the same architecture as its 7890 GC and 7693A automatic liquid sampler. An inert sample pathway carries the vapor to the GC without analyte loss or degradation. An automatic leak check confirms each vial is sealed before the run starts. The sampler stores up to 32 user-defined headspace methods, plus five presets, and up to 9 sequences. An operator can run it standalone from a chemical-resistant keypad or over LAN through OpenLab CDS ChemStation, OpenLab CDS EZChrom, or MSD ChemStation. Independent control of vial pressurization and column head pressure keeps sample transfer free of backpressure. Priority sample positions accommodate a late-arriving sample without breaking the sequence. Barometric pressure compensation holds results consistent across instruments and labs. The 7697A runs on hydrogen as a carrier gas. Sleep and Wake modes cut gas and power use between runs.

What each component does

Vapor sampling

Samples the vapor above the sample for volatile analysis, without carrying the liquid or solid matrix into the GC.

Automated sequencing

Runs overnight sequences without an operator, working through the loaded tray on its own schedule.

In this system
Agilent 7697A Headspace G4557A Verified
Oven range 4 to 450°C Verified
7683B Autosampler G2614A Verified
Optional Inlets Optional Detectors Verified
Workstation loaded with software
Included
Specifications

Technical detail

Vial capacity 12 or 111 vials
Stored methods 32 user-defined, plus 5 presets
Stored sequences Up to 9
Carrier gas Compatible with hydrogen
Power modes Sleep and Wake
Condition Certified Refurbished
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 7697A is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Petrochemical

Hydrocarbons and fuels

Food & Beverage / Chemical

Solvents and fatty acids

Petrochemical / Semiconductor / Chemical

Permanent and fixed gases

Environmental / Food & Beverage

Pesticides and halogenated compounds

Environmental / Food & Beverage

Nitrogen and phosphorus pesticides

Petrochemical / Environmental

Sulfur and phosphorus compounds

Environmental

Volatiles and semivolatiles

Pharmaceutical / Cannabis

Residual solvents confirmation

Food & Beverage / Cannabis

Pesticides and terpenes

Condition

Refurbished

Model

7697A

OEM

Agilent Technologies

Financing

Financing Options Available

Put the financing content and link here.

Need a single detector instead?

Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.