15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 6490 Triple Quadrupole LC/MS with a 1290 Infinity HPLC front end, fitted with Agilent’s InfinityLab PFC-Free HPLC Conversion Kit. The 1290 pump and sampler separate the mixture and deliver a reproducible gradient to the source. The 6490’s iFunnel ion source converts the eluent into gas-phase ions with high efficiency. The triple quadrupole isolates a precursor, fragments it, and measures the product ion at trace levels. The conversion kit reduces the PFAS background the LC’s own solvents and components would otherwise introduce. GenTech rebuilds and tests the LC, the source, and the analyzer, then verifies the system end to end.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the 6490 around iFunnel technology, combining Jet Stream thermal gradient focusing, a hexabore capillary, and a dual ion funnel to carry more ions from the source into the analyzer. A curved collision cell steers ions away from neutral background noise before they reach the second quadrupole. Agilent reports sensitivity down to the attogram level for well-behaved compounds. Agilent’s InfinityLab PFC-Free HPLC Conversion Kit reduces the background from per- and polyfluoroalkyl substances that ordinary HPLC solvents and components introduce into a PFAS method. Agilent tested the kit against 38 target analytes and found no background for 36 of them; small traces of two compounds, PFBA and 6:2 FTS, remained detectable even with the full kit and its delay column installed. Agilent does not sell this kit directly to the general public; it typically ships pre-installed on a system already configured for PFAS work.
What each module does
Liquid chromatograph
Separates the mixture and delivers a reproducible gradient to the source. The 1290 Infinity front end runs the same pumps and samplers as a standalone HPLC, rated to 1,200 bar.
PFC-Free Conversion Kit
Replaces solvent-path components prone to PFAS leaching, cutting background contamination for trace fluorochemical methods.
iFunnel ion source
Converts the liquid eluent into gas-phase ions. Jet Stream, a hexabore capillary, and a dual ion funnel work together to carry more ions into the analyzer than a conventional source.
Mass analyzer
Two quadrupoles flank a curved collision cell that steers ions away from neutral background noise. The first selects a precursor, the cell fragments it, and the second measures a product ion at trace levels.
| In this stack | |
| Triple Quadrupole MS G6490A | Verified |
| 1260 Vialsampler G7129A | Verified |
| 1260 Multicolumn Thermostat G7116A | Verified |
| 1260 Diode Array Detector G7115A | Verified |
|
Workstation loaded with software
|
Included |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Ion source | iFunnel (Jet Stream + dual ion funnel) |
| Sensitivity | To the attogram level (Agilent-reported) |
| Collision cell | Curved, off-axis noise rejection |
| Software | MassHunter |
| 1290 Infinity Front End | Agilent HPLC |
| Max pressure | 1,200 bar to 2 mL/min |
| PFC-Free Kit coverage | No background for 36 of 38 analytes tested |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 6490 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
PFAS testing
EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.
Pesticides and mycotoxins
Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.
Trace impurities and cleaning validation
Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.
Quantitative toxicology
Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.
GLP-grade quantitation
Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.
| Condition | Refurbished |
|---|---|
| Model | 6490, 1290 |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a main board instead?
Replacing a failed pump or looking to upgrade your mass spec? Every module in this system is available individually, in stock and performance-verified.









