Agilent 7890B GC with 5975C MSD ONLY $34,999 or $675.19/mo

$34,999.00




Includes:

  • Agilent 7890B GC
    • Dual Split/Splitless
    • Single FID
  • Agilent 5975C MSD
  • Mechanical Pump
  • Data System
  • Warranty Coverage

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

Environmental, forensic, and food-safety methods that identify and confirm compounds by mass run on the GC-MS the Agilent 7890B and 5975C deliver together. The 7890B separates the mixture on a capillary column; the sample crosses a heated transfer line into the 5975C; the source ionizes each compound; the quadrupole scans the mass range or watches selected ions for trace quantitation. GenTech rebuilds, plumbs, and tests the GC’s inlets, detectors, and flow path, then cleans and calibrates the MSD, and verifies the complete system end to end.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Electronic pneumatic control on the 7890B meters carrier and detector gases to 0.001 psi and 0.05 mL/min, compensating for changes in ambient pressure and temperature. The oven programs from 4 to 450 degrees Celsius across 20 ramps and 21 plateaus. The 5975 MSD attached to it runs a hyperbolic quadrupole mass filter covering a mass range of roughly 1.6 to 1,050 u. A Triple-Axis HED-EM detector improves signal-to-noise over the older off-axis detector designs used on earlier Agilent MSDs. Electron ionization produces reproducible, library-searchable spectra; an optional chemical ionization source preserves the molecular ion for confirmation. Agilent ChemStation software controls acquisition and library searching.

What each component does

Inlet

Vaporizes the sample and delivers it to the head of the column. Split/splitless handles routine concentrations; the multimode and PTV inlets add programmed temperature for trace work and thermally fragile compounds.

Column oven

Programs from 4 to 450°C across 20 ramps and 21 plateaus, with fast ramping to 75°C per minute on a 120 V oven and higher on 240 V.

Transfer line and ion source

Carries the separated compounds into the 5975 at controlled temperature. Electron ionization produces reproducible, library-searchable spectra; optional chemical ionization preserves the molecular ion for confirmation.

Mass analyzer

A hyperbolic quadrupole filters ions by mass. It scans a full spectrum for identification or holds on selected ions for the lowest detection limits in quantitation.

In this system
Agilent 7890B G3440B Verified
5975C TAD inert MSD G3171A Verified
7683B Autosampler G2614A Optional
Optional Inlets Optional Detectors Verified
Workstation loaded with software
Included
Specifications

Technical detail

Oven range 4 to 450°C, 20 ramps/21 plateaus
EPC precision 0.001 psi, 0.05 mL/min
Mass range ~1.6 to 1,050 u
Detector Triple-Axis HED-EM
Ionization EI standard; optional CI
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 7890B is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Petrochemical

Hydrocarbons and fuels

Food & Beverage / Chemical

Solvents and fatty acids

Petrochemical / Semiconductor / Chemical

Permanent and fixed gases

Environmental / Food & Beverage

Pesticides and halogenated compounds

Environmental / Food & Beverage

Nitrogen and phosphorus pesticides

Petrochemical / Environmental

Sulfur and phosphorus compounds

Environmental

Volatiles and semivolatiles

Pharmaceutical / Cannabis

Residual solvents confirmation

Food & Beverage / Cannabis

Pesticides and terpenes

Weight 200 lbs
Dimensions 40 × 24 × 40 in
OEM

Agilent Technologies

Financing

Financing Options Available

Put the financing content and link here.

Need a single detector instead?

Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.