Agilent 8890 Refurbished Side GenTech Side
Certified Refurbished · Gas Chromatography

Agilent 8890 GC System




Includes:

  • Agilent 8890 GC
    • Dual Flame Ionization Detector
    • Dual Split/Splitless (S/S) inlets
    • Browser interface optimized for mobile viewing
  • Data System
  • Warranty Coverage
Verified against OEM and published benchmarks
1-year warranty available
Installation and familiarization available
Financing available

Options:

  • GC Starter Kit
  • Liquid, Headspace, or SPME Samplers
  • Workbench
  • Installation & Familiarization
  • Extended Warranty
  • Financing Available


15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

Most petrochemical, environmental, and food-safety methods call for the capillary GC separations the Agilent 8890 runs. Electronic pneumatic control meters the carrier gas to 0.001 psi; the heated inlet vaporizes the sample and carries it onto the column; the oven programs from 4 to 450°C; the detector measures each compound as it elutes. GenTech rebuilds, plumbs, and tests the inlets, detectors, and flow path. You receive a GC that arrives verified and ready to run your methods.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent positions the 8890 as an intelligent, high-performance GC built for labs where accurate results and instrument uptime matter most. The system pairs flexible configuration with built-in GC intelligence: autonomous monitoring, self-guided maintenance procedures, and remote connectivity. Agilent’s browser interface extends that monitoring outside the lab; a chemist can check system logs and run diagnostics from a browser, on-site or off. A 7-inch capacitive touchscreen gives a visual report of the system configuration, the active method, and the flow path. It also handles routine maintenance and status checks at the bench. The 8890 carries enhanced Capillary Flow Technology hardware and simplified data system software for backflush setup and operation. Sleep Mode drops power and gas consumption during idle periods; Wake Mode brings the system back to full throughput on demand.

What each component does

Inlet

Vaporizes the sample and delivers it to the head of the column. Split/splitless handles routine concentrations; the multimode and PTV inlets add programmed temperature for trace work and thermally fragile compounds; cool on-column places the sample directly on the column for the heaviest analytes. The 8890 holds up to two inlets.

Column oven

Programs from 4 to 450°C across 20 ramps and 21 plateaus, with fast ramping to 75°C per minute on a 120 V oven and higher on 240 V. Faster ramps and a four-minute cool-down cut cycle time at the lowest cost per sample.

Electronic pneumatic control

Meters carrier and detector gases to 0.001 psi and 0.05 mL/min and compensates for changes in ambient pressure and temperature. Precise pneumatics are the basis for the retention-time repeatability every quantitative method depends on.

Detectors

The 8890 carries up to four detectors matched to the chemistry: FID for hydrocarbons and general organics, TCD for fixed gases, micro-ECD for halogens and pesticides, NPD for nitrogen and phosphorus, and FPD for sulfur and phosphorus. Flow splitting sends one injection to two detectors for more information per run.

Capillary Flow Technology

Provides leak-free, in-oven connections for backflush, Deans-switch heart-cutting, and two-dimensional GC without cryogen. Backflush vents heavy matrix before it reaches the detector or the MS source, which protects the flow path and removes carryover.

In this system
Agilent 8890 G3540A Verified
Detectors Dual FID Verified
Inlets Dual Split/Splitless (S/S) Verified
Workstation with preloaded software Included
Specifications

Technical detail

Oven range 4 to 450°C
Oven programming 20 ramps, 21 plateaus
Fast ramp (120 V oven) To 75°C/min
EPC resolution 0.001 psi, 0.05 mL/min
Inlets Up to two
Detectors Up to four
Interface Touchscreen and browser control
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 8890 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Petrochemical

Hydrocarbons and fuels

Food & Beverage / Chemical

Solvents and fatty acids

Petrochemical / Semiconductor / Chemical

Permanent and fixed gases

Environmental / Food & Beverage

Pesticides and halogenated compounds

Environmental / Food & Beverage

Nitrogen and phosphorus pesticides

Petrochemical / Environmental

Sulfur and phosphorus compounds

Environmental

Volatiles and semivolatiles

Pharmaceutical / Cannabis

Residual solvents confirmation

Food & Beverage / Cannabis

Pesticides and terpenes

Model

8890

Condition

Refurbished

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single detector instead?

Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.

15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

Most petrochemical, environmental, and food-safety methods call for the capillary GC separations the Agilent 8890 runs. Electronic pneumatic control meters the carrier gas to 0.001 psi; the heated inlet vaporizes the sample and carries it onto the column; the oven programs from 4 to 450°C; the detector measures each compound as it elutes. GenTech rebuilds, plumbs, and tests the inlets, detectors, and flow path. You receive a GC that arrives verified and ready to run your methods.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent positions the 8890 as an intelligent, high-performance GC built for labs where accurate results and instrument uptime matter most. The system pairs flexible configuration with built-in GC intelligence: autonomous monitoring, self-guided maintenance procedures, and remote connectivity. Agilent’s browser interface extends that monitoring outside the lab; a chemist can check system logs and run diagnostics from a browser, on-site or off. A 7-inch capacitive touchscreen gives a visual report of the system configuration, the active method, and the flow path. It also handles routine maintenance and status checks at the bench. The 8890 carries enhanced Capillary Flow Technology hardware and simplified data system software for backflush setup and operation. Sleep Mode drops power and gas consumption during idle periods; Wake Mode brings the system back to full throughput on demand.

What each component does

Inlet

Vaporizes the sample and delivers it to the head of the column. Split/splitless handles routine concentrations; the multimode and PTV inlets add programmed temperature for trace work and thermally fragile compounds; cool on-column places the sample directly on the column for the heaviest analytes. The 8890 holds up to two inlets.

Column oven

Programs from 4 to 450°C across 20 ramps and 21 plateaus, with fast ramping to 75°C per minute on a 120 V oven and higher on 240 V. Faster ramps and a four-minute cool-down cut cycle time at the lowest cost per sample.

Electronic pneumatic control

Meters carrier and detector gases to 0.001 psi and 0.05 mL/min and compensates for changes in ambient pressure and temperature. Precise pneumatics are the basis for the retention-time repeatability every quantitative method depends on.

Detectors

The 8890 carries up to four detectors matched to the chemistry: FID for hydrocarbons and general organics, TCD for fixed gases, micro-ECD for halogens and pesticides, NPD for nitrogen and phosphorus, and FPD for sulfur and phosphorus. Flow splitting sends one injection to two detectors for more information per run.

Capillary Flow Technology

Provides leak-free, in-oven connections for backflush, Deans-switch heart-cutting, and two-dimensional GC without cryogen. Backflush vents heavy matrix before it reaches the detector or the MS source, which protects the flow path and removes carryover.

In this system
Agilent 8890 G3540A Verified
5975C MSD G3171A Verified
7683B Autosampler G2614A Verified
Optional Inlets Optional Detectors Verified
Workstation loaded with software
Included
Specifications

Technical detail

Oven range 4 to 450°C
Oven programming 20 ramps, 21 plateaus
Fast ramp (120 V oven) To 75°C/min
EPC resolution 0.001 psi, 0.05 mL/min
Inlets Up to two
Detectors Up to four
Interface Touchscreen and browser control
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 8890 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Petrochemical

Hydrocarbons and fuels

Food & Beverage / Chemical

Solvents and fatty acids

Petrochemical / Semiconductor / Chemical

Permanent and fixed gases

Environmental / Food & Beverage

Pesticides and halogenated compounds

Environmental / Food & Beverage

Nitrogen and phosphorus pesticides

Petrochemical / Environmental

Sulfur and phosphorus compounds

Environmental

Volatiles and semivolatiles

Pharmaceutical / Cannabis

Residual solvents confirmation

Food & Beverage / Cannabis

Pesticides and terpenes

Model

8890

Condition

Refurbished

OEM

Agilent Technologies

Financing

Financing Options Available

Put the financing content and link here.

Need a single detector instead?

Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.