Agilent 1200 Autosampler Thermostat Right Angle
Certified Refurbished · Liquid Chromatography

Agilent 1200 HPLC ALS Thermostat (G1330B)




The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system. Equipped with a cooling/heating module and Peltier elements, the G1330B assures efficient temperature control of the sample vials.

Includes:

  • Agilent 1200 HPLC ALS Thermostat (G1330B)
  • In-House Warranty Coverage

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 1200 Series G1330B ALS thermostat. It holds samples at a set temperature in the autosampler tray, protecting temperature-sensitive samples before injection.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this module

Agilent built the G1330B around the same Peltier-controlled heat exchangers as the G1330A, with a settable temperature range of 4 to 40 degrees Celsius in 1-degree increments. Temperature accuracy holds to between -1 and +4 degrees Celsius at a 4-degree setpoint when ambient temperature stays under 25 degrees Celsius and humidity under 50 percent, widening to +5 degrees Celsius above that ambient threshold. The thermostat pairs with the G1389A, G1367A, or G2260A autosampler module over a control cable, with each module keeping its own power supply. It works with other 1200 or 1290 Infinity Series modules, or with other LC systems that have adequate remote control inputs and outputs, controlled from the Agilent Instant Pilot or from Agilent’s own LC control software. The thermostatted sample tray holds 100 1.8-milliliter vials, or two well plates plus 10 1.8-milliliter vials. The unit operates up to 2000 meters altitude and tolerates humidity under 95 percent at 40 degrees Celsius without condensing. It measures 13.5 by 17 by 5.5 inches and weighs 20.7 kilograms.

What this module does

Sample thermostatting

Holds samples in the autosampler tray at a set temperature, using Peltier-controlled heating and cooling, protecting temperature-sensitive samples before injection.

Autosampler pairing

Connects to a G1389A, G1367A, or G2260A autosampler module over a control cable, each keeping its own power supply.

In this stack
Agilent 1200 ALS Thermostat G1330B Verified
Specifications

Technical detail

Temperature range 4 to 40°C, 1°C increments
Temperature accuracy -1 to +4°C (below 25°C ambient)
Sample capacity support 100 x 1.8-mL vials, or 2 wellplates + 10 vials
Weight / dimensions 20.7 kg, 34.5 x 43.5 x 14 cm
Compatible autosamplers G1389A, G1367A, G2260A
Key Features Peltier Control, Air Circulation, Condensation Management, System Integration via CAN interface

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Assay, Impurity and dissolution

The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.

Environmental

EPA HPLC methods

Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.

Food & Beverage

Additives and vitamins

The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.

Cannabis & Hemp

Cannabinoid potency

HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.

Natural Products

Botanical actives

Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.

Clinical & Forensic

Screening and drug monitoring

The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.

Chemical & Materials

Purity and additives

Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.

Method Development

Four-solvent scouting

Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.

LC/MS Front End

Proteomics, metabolomics, lipidomics

Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.

Model

G1330B

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single module instead?

Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.