AB Sciex 3200 Triple Quad LC/MS angled view

AB Sciex 3200 Triple Quad LC/MS




Includes:

  • AB Sciex 3200 Triple Quad LC/MS
  • Mechanical Pump
  • Data System
  • Warranty Coverage

Options



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished AB Sciex API 3200 triple quadrupole mass spectrometer. This listing is the bare MS; a compatible HPLC front end is sold separately or paired at the bench. The source converts the LC eluent into gas-phase ions. The triple quadrupole isolates a precursor, fragments it, and measures the product ion for trace-level quantitation.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

The API 3200 runs a Turbo V ion source, interchangeable with TurboIonSpray, APCI, DuoSpray, or PhotoSpray probes depending on the application. A patented LINAC collision cell drives ion transfer between the second and third quadrupoles. A pulse-counting channel electron multiplier detects ions across a dynamic range of five orders of magnitude. Mass accuracy holds to 0.1 Da over 8 hours and 0.15 Da over 24 hours. Polarity switches in 700 milliseconds. The quadrupole scans as fast as 24,000 Da per second. SCIEX discontinued the API 3200 and no longer manufactures it, though refurbished and used units remain available through the secondary market.

 

What each module does

Ion source

A Turbo V source converts the liquid eluent into gas-phase ions, with interchangeable ESI, APCI, DuoSpray, or PhotoSpray probes.

Mass analyzer

Two quadrupoles flank a patented LINAC collision cell. The first selects a precursor, the cell fragments it, and the second measures a product ion for trace-level quantitation.

Vacuum and detection

Stages the ions from atmosphere to high vacuum, then counts them with a pulse-counting channel electron multiplier.

In this stack
AB Sciex API 3200 Triple Quad API 3200 Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Analyzer Triple quadrupole
Scan speed Up to 24,000 Da/sec
Polarity switching 700 ms
Mass accuracy 0.1 Da/8 hr, 0.15 Da/24 hr
Dynamic range 5 orders of magnitude

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The AB Sciex API 3200 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Environmental

PFAS testing

EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.

Food & Beverage / Cannabis

Pesticides and mycotoxins

Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.

Pharmaceutical

Trace impurities and cleaning validation

Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.

Clinical & Forensic

Quantitative toxicology

Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.

Regulated Bioanalysis

GLP-grade quantitation

Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a main board instead?

Replacing a failed pump or looking to upgrade your mass spec? Every module in this system is available individually, in stock and performance-verified.