Agilent 1100 Fraction Collector (G1364A)




Includes:

  • Agilent 1100 Fraction Collector (G1364A)
  • In-House Warranty Coverage
Verified against OEM and published benchmarks
1-year warranty available
Installation and familiarization available
Financing available

Options:



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 1100 G1364A automatic fraction collector. It collects separated fractions by time, peak, or threshold for preparative work.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the G1364A around three operating modes. Discrete Fractions, the default mode, diverts flow to waste while the collector moves between vessel positions. Continuous Flow, available only with deep well plates, moves between positions without diverting flow. Needle Into Location pushes the needle into the vessel for capped vials, tubes, and well plates with closing mats. Trigger modes cover time slices, peak detection with threshold or slope settings, a timetable combining both, and manual triggering, the last of which requires the G1323B Control Module. Maximum tube or plate height runs to 48 millimeters, with tube volume to about 20 milliliters, or unlimited using funnels into external containers. Maximum flow rate reaches 10 milliliters per minute, limited by viscosity and back pressure to 6 bar at the diverter valve. Leak detection, error detection and display, and an exhaust fan for hazardous vapor extraction cover safety. The collector fully supports Agilent’s 1200 Series DAD, MWD, and fluorescence detectors, along with the G1946 and G1956 LC-MSD, as trigger sources; other detectors connect but without the same integration.

 

What each module does

Fraction collection

Gathers purified fractions from a preparative separation, triggered by time, by a peak threshold, or by a timetable combining both.

In this stack
Agilent 1100 Fraction Collector G1364A Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Operating modes Discrete fractions, continuous flow, needle-into-location
Trigger modes Time slices, peak, timetable, manual (with G1323B)
Max tube/plate height 48 mm
Max flow rate 10 mL/min, up to 6 bar at diverter valve
Detector support 1200 Series DAD/MWD/FLD, G1946/G1956 LC-MSD
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1100 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Assay, Impurity and dissolution

The 1100 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.

Environmental

EPA HPLC methods

Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.

Food & Beverage

Additives and vitamins

The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.

Cannabis & Hemp

Cannabinoid potency

HPLC with UV detection is the reference technique for potency. The 1100 resolves the major cannabinoids for compliance and label-claim testing.

Natural Products

Botanical actives

Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.

Clinical & Forensic

Screening and drug monitoring

The 1100 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.

Chemical & Materials

Purity and additives

Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.

Method Development

Four-solvent scouting

Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.

LC/MS Front End

Proteomics, metabolomics, lipidomics

Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1100 serves as the front end feeding your MS or fraction collector.

OEM

Agilent Technologies

Model

G1364A

Conditon

Refurbished

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single module instead?

Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.