15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
This turnkey, professionally refurbished Agilent 6410 Triple Quad LC/MS system delivers reliable, quantitative performance for demanding target compound analysis and routine screening. The system is paired with a robust Agilent 1100 Series HPLC front end, featuring a binary pump for high-pressure gradient precision and a standard autosampler for dependable injection repeatability. Your purchase includes a dedicated roughing mechanical vacuum pump, computer data system pre-loaded with software, and comprehensive warranty coverage to ensure complete peace of mind and immediate operational uptime in your laboratory.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent engineered the 6410 Triple Quadrupole LC/MS to bring routine, everyday sensitivity and ruggedness to laboratories performing quantitative analysis. The platform is widely recognized for its diagnostic durability, utilizing a high-efficiency collision cell and hyperbolic quadrupoles to provide excellent ion transmission and stable mass resolution across its entire mass range. Combined with the industry-standard 1100 Series HPLC front end, the system is positioned as a workhorse solution for food safety, environmental analysis, clinical research, and forensic toxicology, offering high-speed MS/MS transitions alongside automated, unattended sequence execution.
What each component does
- Agilent 6410 Triple Quadrupole Mass Spectrometer: Detects and quantifies trace compounds in complex matrices using tandem MS/MS technology to isolate specific precursor ions and monitor unique product ion fragments (MRM mode).
- Agilent 1100 Series Binary Pump (G1312A): Delivers highly precise and reproducible solvent gradients by utilizing two independent high-pressure pistons, ensuring consistent mobile phase composition for stable chromatographic retention times.
- Agilent 1100 Series Autosampler (G1313A ): Draws accurate sample volumes using an X-Z-Theta robotic arm and injects them onto the column under high pressure, maintaining an automated sequence without operator intervention.
- Mechanical Roughing Pump: Generates the crucial primary vacuum required to support the high-vacuum turbo pumps inside the mass spectrometer housing.
- Data System: Serves as the centralized software hub for controlling instrument parameters, acquiring chromatographic and mass data, and performing quantitative batch report analysis.
| In this stack | |
| Agilent 6410 Triple Quadrupole MS G6410 | Verified |
| Agilent 1100 HPLC Front End Binary Pump (G1312A) Autosampler (G1313A) | Verified |
| Mechanical Pump | Verified |
| Warranty Coverage Extended Options Available | Included |
| Workstation with preloaded software | Included |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| Mass Range | m/z 15 to 1,650 |
| Mass Resolution | Full width at half maximum (FWHM) selectable down to 0.7 Da (unit resolution) |
| Scan Modes | MRM (Multiple Reaction Monitoring), Product Ion, Precursor Ion, Neutral Loss, and Single MS scans |
| Maximum LC Operating Pressure | 400 bar (5,880 psi) |
| HPLC Flow Rate Range | 0.001 to 5.0 mL/min (recommended analytical range up to 2.0 mL/min) |
| Autosampler Injection Range | 0.1 µL to 100 µL standard |
| Autosampler Tray Capacity | 100 x 2-mL standard vials |
| Ion Source Options | Electrospray Ionization (ESI) or Atmospheric Pressure Chemical Ionization (APCI) |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 6410 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
PFAS testing
EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.
Pesticides and mycotoxins
Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.
Trace impurities and cleaning validation
Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.
Quantitative toxicology
Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.
GLP-grade quantitation
Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.
| Condition | Refurbished |
|---|---|
| Model | 6410, 1100 |
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a main board instead?