Agilent 6430 Triple Quad LC/MS $25,000 or $549.82/mo.

$25,000.00

Includes:

  • Agilent 6430 Triple Quad LC/MS
  • Mechanical Pump
  • Data System
  • Warranty Coverage

Options:

15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

Pharmaceutical, environmental, and clinical methods that quantify trace compounds by mass run on the LC-MS the Agilent 6430 delivers. The liquid chromatograph separates the mixture; the ion source converts the eluent into gas-phase ions; the triple quadrupole isolates a precursor, fragments it, and measures the product ions down to parts per trillion. GenTech rebuilds and tests the LC, the source, and the analyzer, then verifies the system end to end. You receive an LC-MS that arrives tuned and ready to run your methods.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the 6430 as a step up from the entry-level 6410, adding a second turbo pump, improved pumping in the second vacuum stage, and updated collision cell lenses. MS cycle times run as short as 100 milliseconds, capturing at least ten data points across a one-second peak. Dwell time runs as low as 1 millisecond. A resistively coated capillary lets the instrument switch polarity and resume data acquisition within 30 milliseconds. The system supports up to 19,800 MRM transitions, with up to 4,000 dynamic MRM transitions per method. Agilent rates sensitivity at 1 picogram of reserpine on-column, with a signal-to-noise ratio around 300 to 1. Mass resolution runs to 0.5 Da full width at half maximum with manual tuning, or 0.7 Da with autotune. MassHunter software controls acquisition and data analysis. Agilent Jet Stream technology is not part of the 6430; that ion source is reserved for the 6460 and higher models in the triple quadrupole line.

 

What each module does

Liquid chromatograph

Separates the mixture and delivers a reproducible gradient to the source. This listing does not specify a bundled HPLC brand; a compatible front end is sold separately or paired at the bench.

Ion source

Converts the liquid eluent into gas-phase ions, compatible with Agilent’s HPLC-Chip interface for chip-based separations.

Mass analyzer

Two quadrupoles flank a collision cell, with a second turbo pump and updated collision cell lenses over the entry-level 6410. The first selects a precursor, the cell fragments it, and the second measures a product ion, which gives the selectivity and sensitivity that trace quantitation in complex matrices demands.

Vacuum and detection

Stages the ions from atmosphere to high vacuum, then counts them at the detector.

In this stack
Triple Quadrupole MS G6430A Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

MS cycle time As short as 100 ms
Dwell time As low as 1 ms
Polarity switching 30 ms
MRM capacity Up to 19,800 transitions (4,000 dynamic)
HPLC front end Sold separately; pairs with 1100 or 1200 Series
Sensitivity 1 pg reserpine, ~300:1 S/N
Mass resolution 0.5 Da (manual), 0.7 Da (autotune)

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 6430 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Environmental

PFAS testing

EPA Method 537.1 and similar state programs require quantitation of per- and polyfluoroalkyl substances in drinking water at low parts-per-trillion levels, a sensitivity range triple quadrupole MS is built to reach.

Food & Beverage / Cannabis

Pesticides and mycotoxins

Multi-residue pesticide panels and mycotoxin screens in food and cannabis testing often cover more than 100 compounds in a single run, each requiring the selectivity a triple quadrupole provides against a complex matrix background.

Pharmaceutical

Trace impurities and cleaning validation

Pharmaceutical cleaning validation protocols confirm that equipment surfaces carry no detectable residue of the previous product, often down to sub-part-per-billion swab or rinse limits.

Clinical & Forensic

Quantitative toxicology

Forensic and clinical toxicology panels quantify drugs and metabolites in blood, urine, or tissue against legally defensible limits, where a triple quadrupole’s selectivity rules out false positives from matrix interferences.

Regulated Bioanalysis

GLP-grade quantitation

Good Laboratory Practice studies require documented, audit-ready quantitation with full method validation, a standard regulated bioanalysis labs run routinely on triple quadrupole platforms.

Weight 400 lbs
Dimensions 48 × 48 × 40 in
Condition

Refurbished

Model

6430

OEM

Agilent

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a main board instead?

Replacing a failed pump or looking to upgrade your mass spec? Every module in this system is available individually, in stock and performance-verified.