Agilent 7500 icp/ms left angle
Agilent 7500 icp/ms right angle

Agilent 7500 ICP-MS




Includes:

  • Agilent 7500 ICP-MS
  • Mechanical Pump
  • Chiller
  • Data System
  • Warranty Coverage

Options



15-Day

Refurbishment cadence

OEM-Spec

Verified against OEM and published benchmarks; report included.

On-Staff

Solution Scientists

Since 1996

Three decades supporting labs

The System

What you are buying

A refurbished Agilent 7500 ICP-MS. The nebulizer forms an aerosol, the argon plasma ionizes the elements, the interface samples the ions into vacuum, the collision cell removes interferences, and the quadrupole measures each element to trace levels.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the Octopole Reaction System into the 7500 series to remove polyatomic interferences without swapping methods between elements. The ORS runs helium collision mode with kinetic energy discrimination, or a reactive cell gas for mass-shift chemistry, using the same octopole cell and conditions across the full element suite. An off-axis Omega ion lens gives the system high ion transmission and low background, which Agilent points to for its detection limits. Agilent states the 7500 series delivers the best detection limits of any multi-element technique, with a complete elemental panel achievable in under five minutes per sample. ChemStation software runs the instrument and, from revision B.03.02, adds pre-emptive rinsing and the ability to sequence GC or LC methods directly from the ICP-MS sequence table for speciation work.

 

What each module does

Sample introduction

Nebulizer and spray chamber form a steady aerosol.

Plasma and interface

The argon plasma ionizes the elements. Sampler and skimmer cones draw the ions into vacuum.

Collision cell and quadrupole

Helium mode removes polyatomic interferences. The quadrupole separates ions by mass and the detector counts them across a wide dynamic range.

In this stack
Agilent 7500 ICP-MS G7111B Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Interference removal Octopole Reaction System (ORS)
Collision gas Helium (KED) or reactive cell gas
Ion lens Off-axis Omega lens
Mass analyzer Quadrupole
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 7500 ICP/MS is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Elemental impurities

USP <232>/<233> and ICH Q3D set limits on catalyst and process-related elemental impurities in drug substances and products. ICP-MS quantifies each targeted element against those limits in a single run.

Environmental

Metals in water and soil

EPA methods 200.8 and 6020B call for ICP-MS to quantify regulated metals in drinking water, wastewater, and soil digests, often down to parts-per-trillion levels.

Food & Beverage

Heavy metals

Food safety and cannabis testing programs screen for arsenic, cadmium, lead, and mercury, the four heavy metals most state and federal programs regulate by ICP-MS.

Semiconductor

Trace metals in process chemicals

Semiconductor fabs test process chemicals like acids and solvents for trace metal contamination that could damage a wafer, often specifying results at parts-per-trillion levels.

Condition

Refurbished

Model

G3152A

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single part instead?

Replacing a failed nebulizer or expanding an existing instrument? Every module in this system is available individually, in stock and performance-verified.