What you are buying

A refurbished Agilent 1260 I DAD, a diode array detector. It records full UV-visible spectra across the run for identification and peak purity.

Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.

What Agilent says about this platform

Agilent built the 1260 Infinity DAD family around a 1024-element photodiode array with deuterium and tungsten lamps, covering 190 to 950 nanometers. Data rate reaches up to 80 Hz, with no loss of sensitivity across up to 8 simultaneous wavelengths. Short-term noise runs about 0.7 to 0.8 x 10-5 AU at 254 and 750 nanometers, with drift under 0.9 x 10-3 AU per hour at 254 nanometers. Linear absorbance extends past 2 AU. A built-in holmium oxide filter verifies wavelength accuracy to within 1 nanometer, backed by self-calibration against the deuterium lamp’s own spectral lines. A programmable slit at 1, 2, 4, 8, or 16 nanometers trades sensitivity against baseline noise for each method. Agilent’s E-PAC packaging concept houses the mechanical and electronic assemblies in molded foam layers, which speeds assembly and disassembly and channels cooling air through the case.

 

What each module does

Binary pumping

Delivers a two-solvent high-pressure gradient at constant, low-pulse flow. Stable, low-pulse flow is the basis for the retention-time reproducibility every quantitative method depends on. Rated to 600 bar.

In this stack
1260 Infinity DAD G1315 C/D or G4212 A/B Verified
1260 Vialsampler G7129A Verified
1260 Multicolumn Thermostat G7116A Verified
1260 Diode Array Detector G7115A Verified
Workstation loaded with software
Included
Specifications

Technical detail

Detection type 1024-element photodiode array
Wavelength range 190 to 950 nm
Data rate Up to 80 Hz
Simultaneous wavelengths Up to 8
Wavelength accuracy ±1 nm, holmium oxide verification
Software Loaded on workstation

*OEM specifications for brand new instrument.

Certification

What “GenTech Certified” means

Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.

1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.

2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.

3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.

4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.

5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.

Application Fit

Labs that run this system

The 1260 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.

Pharmaceutical QC

Assay, Impurity and dissolution

The 1260 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.

Environmental

EPA HPLC methods

Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.

Food & Beverage

Additives and vitamins

The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.

Cannabis & Hemp

Cannabinoid potency

HPLC with UV detection is the reference technique for potency. The 1260 resolves the major cannabinoids for compliance and label-claim testing.

Natural Products

Botanical actives

Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.

Clinical & Forensic

Screening and drug monitoring

The 1260 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.

Chemical & Materials

Purity and additives

Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.

Method Development

Four-solvent scouting

Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.

LC/MS Front End

Proteomics, metabolomics, lipidomics

Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.

Condition

Refurbished

Model

G1315D

OEM

Agilent Technologies

Financing

Financing Options Available

Financing Options Available.  Finance Builder.

Need a single module instead?

Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.