A refurbished Agilent 1100 nano pump. It delivers nanoliter-per-minute flow for high-resolution separations and high-sensitivity nanospray MS work.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G2226A around two identical pumping units in a single housing, which form gradients through high-pressure mixing. A solvent selection valve adds flexibility in solvent choice. Electronic Flow Control adjusts flow in real time across 0.1 to 1 microliter per minute, with a settable column flow range of 0.01 to 4 microliters per minute, extending to 2500 microliters per minute if the electronic flow control is bypassed. Composition precision holds under 0.2 percent standard deviation at 500 nanoliters per minute under default settings. Delay volume runs about 300 nanoliters from the flow control to the pump outlet at flows up to 4 microliters per minute. Micro vacuum degassing keeps internal volume to 1 milliliter per channel for fast solvent changeover. A handheld controller runs the pump locally. Agilent ChemStation adds extensive diagnostics, error detection, and display. Early Maintenance Feedback tracks seal wear and pumped volume against user-set limits. Built-in leak detection shuts the pump down safely if a seal fails.
What each module does
Nanoflow pumping
Delivers nanoliter-per-minute flow with electronic flow control, matched to high-resolution separations and high-sensitivity nanospray MS work such as proteomics.
| In this stack | |
| Agilent 1100 Nano Pump G2226A | Verified |
| Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system. | |
Technical detail
| EFC flow range | 0.1 to 1 µL/min |
| Settable flow range | 0.01 to 4 µL/min (to 2,500 µL/min, EFC bypassed) |
| Composition precision | Under 0.2% SD at 500 nL/min |
| Delay volume | ~300 nL to 4 µL/min |
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1100 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1100 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1100 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1100 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1100 serves as the front end feeding your MS or fraction collector.
| Model | G2226A |
|---|---|
| OEM | Agilent Technologies |
| Financing | Financing Options Available |
Financing Options Available. Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.